Installation InstruCtions (cont'd)
Temperature-Pressure Relief Valve
A WARNING
At the time of manufacturethis water heater was provided with a
by a nationallyrecognizedtesting laboratorythat maintains periodic mspec_onof productionof listedequipmentor mate- rials, as meeting the requirements for Relief Valves and
AutomaticGasShutoffDevicesfor Hot Water SupplySystems, and the latest edition of ANSI Z21.22 and the code require- meritsof ASME.If replaced,the valvemustmeet the require- mentsoflocalcodes,but not lessthan a combinationtempera-
ture and pressurereliefvalvecertifiedas meetingthe require- ments for ReliefValvesandAutomatic GasShutoffDevicesfor
Hot Water SupplySystems,ANSI Z21.22bya nationally recog- nized testinglaboratorythat maintainsperiodicinspectionof productionof listedequipmentor material_
The valvemust be marked wit(1a maximum set pressurenot to exceed the marked hydrostaticworking pressureof the water heater (150 IbsJsqin. .) and a dischargecapacitynot less than the water heater input rate asshownon the modelrating plate. (Electric heaters - watts dividedby 1000 x 3415 equal BTU/Hr. rate.)
Yourlocaljurisdictionalauthority,whilemandating the useof a
Compliancewith suchlocal requirementsmustbe satisfiedby the installeror enduser of the water heaterwith a locallypre-
nated openingin the water heater in placeof the factory fur- nishedvalve.
Forsafeoperationof the water heater,the relief valvemustnot
be removed from it'sdesignatedopeningor plugged.
The
Positionthe valvedownwardand providetubingsothat anydis-
chargewill exit onlywithin 6 inchesabove,or at anydistance belowthe structuralfloor. Be certainthat no contactis made
with any liveelectricalpart.The dischargeopeningmustnot be blockedor reduced in sizeunder any circumstancesExcessive. length,over 30 feet, or useof more than fourelbowscancause restriction andreducethedischargecapacityofthevalve.
No valveor otherobstructionisto be placedbetweenthe relief valveand the tank. Do not connecttubingdi_ctly to discharge
drainunlessa 6"air gapisprovidedTo. preventbodilyinjury,haz- ard to life,or propertydamage,the relief valvemust be allowed to dischargewaterin quantitiesshouldcircumstancesdemand.If the dischargepipeis not connectedto a drainor other suitable
means,the waterflowmaycausepropertydamage. The DischargePipe:
•Must not be smallerin size than the outlet pipesize of the valve,or haveanyreducing couplingsor other restrlction_
•Mustnot bepluggedor blocked.
Mustbeof materiallistedfor hot waterdistribution.
Must be installedso as to allowcompletedrainageof both the
Mustterminateat an adequatedrain.
Mustnot haveanyvalvebetweenthe reliefvalvaand tank.
&WARNING
The
ensurethat (I) no one is in front of or aroundthe outlet of the
ffafter manually operating the valve, it fails.to completely reset and continuesto release watar, immedmatelyclosethe cold water inlet to the water heater, follow the draining
instructions,and replace the
HOT | COLD |
SHUT OFF
VALVE
)_PRESSURE
RELIEF VALVE
PIPE (Do not cap
or plug)
FLOOR DRAIN
RELIEFVALVEOPENING
At the timeof manufacture,this waterheaterwasprovidedwith a combinationtem-
safeoperation of the water heater,the relief valve must not be removed from its des-
Fgnatedpointofinstallationor plugged.
Your localiurisdictional authority, while mandating the use of a
Compliancewith suchlocal requirementsmust be satisfied by the instalieror end user of the water heater with a locally prescribed
See manual