Water Piping

GAS VENT

Water Piping

INLET AIR DUCT

FIGURE 13.

Alternatively a single permanent opening may be used when communicating directly with the outdoors, or with spaces that freely communicate with the outdoors. The opening shall have a minimum free area of 1 square inch per 3,000 BTU per hour (8.3 cm2/kW) of total input rating of all equipment in the enclosure. See Figure 13A.

OR

GAS VENT

OPENING

LOCATION

FIGURE 13A.

Louvers and Grilles: In calculating free area, consideration shall be given to the blocking effect of louvers, grilles or screens protecting openings. Screens used shall not be smalter than 1/4 inch (6.4 mm) mesh. If the free area through a design of louver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If the design and free area is not known, it may be assumed that wood louvers wilt be 20-25 percent free area and metal louvers and grilles wilt have 60-75 percent free area. Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation.

Special Conditions Created by Mechanical Exhausting or Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment.

 

Water temperature

over 125°F

 

(52°C) can cause severe burns

 

instantly resulting in severe injury

 

or death.

 

 

 

 

,)

physically

or mentally

disabled

_)(_

a re at highest riskfor scald injury.

Children,

elderly,

 

and

the

_._

Feel water before bathing or

_.

Temperature

limiting

 

valves

are

 

available.

 

 

 

 

 

Read instruction manual for safe

.

tern perature

setting,

 

 

 

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions.

In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a *mixing valve should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. See Figure 14. Valves for reducing point of use temperature by mixing cold and hot water are also available. Follow manufacturer's instructions for installation of the valves. Before changing the factory setting on the thermostat, read the Temperature Regulation section in this manual.

 

HOoTuWATER

 

COLD

WATER

 

 

 

 

 

TLET

_

 

 

TEMPERED

_]]__J

 

 

 

WATEROUTLET_.T_L.[_,_

_

 

 

+-

+

TO COLD

WATER

 

 

 

INLET ON

 

*NIXING

HOT WATER

WATER

HEATER

 

 

 

 

VALVE

OUTLET ON

 

 

 

 

WATER HEATER

 

 

FIGURE 14.

Toxic Chemical Hazard

• Do not connect to non-potable water system.