Kenmore 153.33262 manual r! l =7_,I,d =I;i, Burner Flames, Emergency Shut Down, Water Temperature

Models: 153.33262 153.33264

1 44
Download 44 pages 3.4 Kb
Page 27
Image 27
Burner Flames

Burner Flames

Inspect the burner flames through the viewport and compare them to the drawings in Figure 31. A properly operating burner should produce a soft blue flame. Blue tips with yellow inner cones are satisfactory. The tips of the flame may have a slight yellow tint. The flame should not be all yellow or have a sharp blue-orange color. Contaminated air may cause an orange colored flame. Contact a qualified technician if the flame is not satisfactory.

FIGURE 31.

should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores, see Figure 24. Follow manufacturer's instructions for installation of the valves. Before changing the factory setting on the thermostat see Table 5 and Figure 32. Using the lowest hot water temperature that meets your needs will also provide the most energy efficient operation of the water heater. Never allow small children to use a hot water tap, or to draw their own bath water. Never leave a child or handicapped person unattended in a bathtub or shower.

NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is recommended by most dishwasher manufacturers.

The thermostat of this water heater has been factory set at its lowest position. It is adjustable and must be reset to the desired temperature setting to reduce the risk of scald injury. The electronic control display temperature should be set at approximately 120°F (49°C) and this is the preferred starting point, see Table 5. Some states have a requirement for a lower setting. If you need hotter water, follow directions for temperature adjustment, but beware of the warnings in this section.

Emergency Shut Down

IMPORTANT: Should overheating occur or the gas supply fails

to shut off, turn off the heater's manual gas control valve and the electrical power. Call a qualified technician.

110(normal shower temp.)

116(pain threshold)

Water Temperature

r! l =7_,I,'[d =I;i

Regulation

Water temperature over 125°F (52°C) can cause servere burns instantly resulting in severe injury or death.

Children, the elderly, and the physically or mentally disabled are at highest risk for scald injury.

Feel water before bathing or showering.

Temperature limiting valves are available.

Read instruction manual for safe

temperature setting.

116

35 minutes

45

minutes

122

1 minute

5

minutes

131

5 seconds

25

seconds

140

2 seconds

5 seconds

149

1 second

2 seconds

154

instantaneous

1 second

(u.s. Govemment Memorandum, C.RS.C., Peter L. Armstrong, Sept. 15,1978)

 

TABLE

5

 

Pressing the "COOLER"(_)button decreases temperature and pressing the "HOTTER"(_)button increases the temperature.

To avoid any unintentional changes in water temperature settings, the control has a tamper resistant feature for changing the temperature setting. To change the temperature setting follow these instructions:

Due to the nature of the typical gas water heater, the water temperature in certain situations may vary up to 30°F (16.7 °C) higher or lower at the point of use such as, bathtubs, showers, sink, etc.

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which wilt satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state taw requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve

1."Unlock" the temperature indicators by holding down both "COOLER" and "HOTTER" temperature adjustment buttons at the same time for one second (See Figure 32). The dis- play will light up. The display will only remain on for 30 sec- onds if no further buttons are pressed. After 30 seconds the control wilt go back to "Lock" mode ("Lock" mode indicates a temperature setting is locked into the control memory).

2.Release both of the temperature adjustment buttons.

A. To decrease the temperature press and release the "COOLER"(_) button until the desired setting is reached.

B. To increase the temperature press and release the "HOTTER"(_) button until the desired setting is reached.

NOTE: Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance. NOTE: During tow demand periods when hot water is not being used, a lower thermostat setting will reduce energy losses and