2 FT. Minimum Above
IJ_L _ Any Object Within
3FT.
Minimum
|
|
| rizontally |
Support Strap_ _ |
|
|
|
|
| , _Type | B Double |
Maintain L | ........... |
| |
Clearance* f |
|
| Wall Vent Pipe |
|
| \ |
|
|
|
| **Maintain |
[] _1 | Vent | Specified | |
| Connector | Clearance | |
|
|
| |
| Slope Up |
| |
| 1/4 | Inch |
|
| Per | Foot |
|
| Minimum |
|
Venting Gas Vent System With Type B Double Wall Vent Pipe,
FIGURE 21.
| Cap |
Maintain Manufacturer's | |
Specified Minimum | Clearance |
| t |
| **Maintain |
Support Strap\ | Specified |
| Clearance |
Maintain
Clearance*
f
Vent Connector
Chimney
Flue Or Masonry
Enclosure
Venting Through Chimney With Type B Double Wall Vent Pipe,
FIGURE 22.
*Maintain vent pipe clearance requirements to local, state and/or the "National Fuel Gas Code", ANSI Z223.1(NFPA
**NFPA211, Standard for Chimneys, Fireplaces, Vents, and Solid
instructions provided with each chimney support assembly. Minimum air space clearance to combustible materials should be maintained as marked on the chimney sections.
Piping Installation
Piping, fittings, and valves should be installed according to the installation drawing (Figure 23). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation.
The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing valve with a bypass should be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures.
IMPORTANT: Heat cannot be applied to the water fittings on the heater as they may contain nonmetallic parts. If solder connections are used, solder the pipe to the adapter before attaching the adapter to the hot and cold water fittings.
IMPORTANT: Always use a good grade of joint compound and be certain that all fittings are drawn up tight.
1.Install the water piping and fittings as shown in Figure 23. Connect the cold water supply (3/4" NPT) to the cold water inlet fitting. Connect the hot water piping (3/4" NPT) to the hot water outlet fitting.
IMPORTANT: Some models may contain energy saving heat traps to prevent the circulation of hot water within the pipes. Do not remove the inserts within the heat traps.
2, The installation of unions in both the hot and cold water supply lines is recommended for ease of removing the water heater for service or replacement.
3, The manufacturer of this water heater recommends installing a mixing valve or an
4.If installing the water heater in a closed water system, install an expansion tank in the cold water line as specified under Closed System/Thermal Expansion.
5.Install a
6.A temperature and pressure relief valve must be installed
in the opening marked "Temperature and Pressure (T & P) Relief Valve" on the water heater. A discharge line must be added to the opening of the T&P Relief Valve. Follow the instructions under Temperature and Pressure Relief Valve.
7.After piping has been properly connected to the water heater, remove the aerator at the nearest hot water faucet. Open the hot water faucet and allow the tank to completely fill with water. To purge the lines of any excess air, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet and check all connections for leaks.
21