Kenmore 153.33264, 153.33262 Electrical Connections, Electric Shock Hazard, Solar Installation

Models: 153.33262 153.33264

1 44
Download 44 pages 3.4 Kb
Page 24
Image 24
Electrical Connections

Electrical Connections

Before plugging in the water heater, always make sure:

The Voltage and frequency correspond to that specified on the water heater.

The electrical outlet has the proper overload fuse or breaker protection.

Unit is to connect to a 120VAC electrical supply outlet (extension cord is not allowed).

IMPORTANT: Do not use an extension cord to connect the water heater to an electrical outlet.

The water heater and the outlet are properly grounded.

Installed in accordance with prevailing provisions of local codes, or in the absence of such, National Electric Code, ANSI/NFPS 70 current edition.

Completely fill the tank with water and check all connections for leaks. Open the nearest hot water faucet and let it run for three (3) minutes to purge the water lines of air and sediment and to ensure complete filling of the tank. The electrical power may then be turned on. Verify proper operation after servicing.

Electric Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Wiring Diagram

FIGURE 27.

Solar Installation

If this water heater is used as a solar storage heater or as a backup for the solar system, the water supply temperatures to the water heater tank may be in excess of 120°F. A mixing valve or other temperature limiting valve must be installed in the water supply line to limit the supply temperature to 120°F.

NOTE: Solar water heating systems can often supply water with temperatures exceeding 180°F and may result in water heater malfunction.

Air Intake

Chamber Fan

Anode

 

Rod

Switch

 

 

 

 

 

 

,' Control Display

 

 

 

 

 

 

 

,///

 

 

 

 

 

 

 

CAUTION:

 

 

 

 

 

 

 

DO NOT USE AN EXTENSION

 

 

 

 

 

 

CORD TO CONNECT THE

Igniter/Flame

 

 

 

 

 

TRANSFORMER TO AN

 

 

 

 

 

ELECTRICAL

OUTLET.

Sense Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FV

 

 

 

 

 

 

 

Sensor

 

CAUTION:

 

 

 

 

Power

Supply

LABEL

ALL

WIRES

PRIOR

TO

 

 

Transformer

DISCONNECTION

WHEN

SERVICING

 

 

CONTROLS.

WIRING ERRORS

CAN

CAUSE

 

IMPROPER

AND

DANGEROUS

OPERATION.

 

VERIFY

PROPER

OPERATION

AFTER

SERVICING.

 

24

Page 24
Image 24
Kenmore 153.33264 Electrical Connections, Electric Shock Hazard, Disconnect power before servicing, Solar Installation