Quadra-Fire 810-02901 7Appliance Set-Up, A. Reversible Top or Rear Flue Adapter, 2 - Rear Vent

Models: CASTINS-CSB 810-03201 810-02901 CASTINS-CWL

1 52
Download 52 pages 40.24 Kb
Page 18
Image 18
7Appliance Set-Up

R

Castile Pellet Insert

7Appliance Set-Up

A. Reversible Top or Rear Flue Adapter

B. Leveling System

 

Top Vent Installation

1.Release ammo can latches on each side. Figure 18.1.

2.Place the reversible adapter in the correct position for your installation.

3.Make sure BOTH latches are in position before securing them.

Rear Vent Installation

1.Remove the 90o adapter and installation screws from the packaging.

2.Attach the 90o adapter onto the vent adapter, using the 3

screws provided. You will need to pre-drill the holes for screw placement. Be sure to adjust the 90o adapter to the desired position for venting before drilling.

3.Silicone the pipe joints according to the Note below.

NOTE: All pipe must be sealed using welded seam pipe whenever possible. Seal pipe joints with high temperature silicone, minimum rate of 5000F (2600C).

Ammo Can Latches

The back legs are adjustable to allow for customized fi t into zero clearance boxes.

1.Loosen 2 top screws and remove 2 bottom screws.

2.Adjust leg to desired height. Leg can slide up (shorter) or down (longer) to level the insert.

3.Tighten 2 top screws.

4.Drill 2 holes for the bottom 2 screws and re-install screws. Figure 18.5.

Loosen top 2 screws and remove bottom 2. Adjust leg to desired height.

Figure 18.4

Drill 2 holes and re-install bottom 2 screws

Figure 18.1 - Top Vent

Figure 18.5

screw

Figure 18.2 - Rear Vent

Figure 18.3 - Rear Vent

Page 18

250-7251G

August 20, 2009

Page 18
Image 18
Quadra-Fire 810-02901 7Appliance Set-Up, A. Reversible Top or Rear Flue Adapter, B. Leveling System, Top Vent Installation