Quadra-Fire 810-03201 B. Full Reline With Outside Air - Vertical, Castile Pellet Insert, Figure

Models: CASTINS-CSB 810-03201 810-02901 CASTINS-CWL

1 52
Download 52 pages 40.24 Kb
Page 16
Image 16
B. Full Reline With Outside Air - Vertical

R

Castile Pellet Insert

B. Full Reline With Outside Air - Vertical

NOTE: Check clearances carefully for this type of instal- lation to ensure adequate room for outside air venting.

NOTE: In Canada only a full reline is allowed per ULC S628, ORD ULC C1482-M1990.

305mm min. above

305mm min. below

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insula- tion such as fiberglass, mineral wool or ceramic.

Do not use high temperature caulk- ing materials to seal any edge to prevent furture serviceability.

Outside Air

Termination

at

Chimney Top

(Vertical)

Figure 16.1

NOTE: In Canada this fi replace insert must be installed with a continous chimney liner a 6 inch (152mm) in diam- eter extending from the fi replace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirments of CAN/ULC-S635, Standard for Lining Systems for Extising Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Sys- tems for New Masonry Chimneys.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fi re offi cials or authorities having jurisdiction about restrictions, installation inspection, and permits.

Page 16

250-7251G

August 20, 2009

Page 16
Image 16
Quadra-Fire 810-03201, CASTINS-CSB, 810-02901 B. Full Reline With Outside Air - Vertical, Castile Pellet Insert, Figure