R
Castile Pellet Insert
C. Outside Air Kit Instructions | D. Zero Clearance Trim Support Instructions |
Parts Included in Kit: 1 piece of 2 inch x 3 ft. flex hose, 2
hose clamps, 1 collar assembly, 1 termination cap assem- NOTE: Only for use on small size panels. bly, 1 air intake channel, 1 trim ring, fasteners. NOTE:
Discard air intake channel, it is not used on this appliance.
Tools Needed: Phillips head screwdriver; wire cutters; hole saw or jig saw.
1. Attach collar assembly to appliance. Figure 19.1. Measure distance from fl oor to air vent opening in appliance and mark location on wall.
Figure 19.2 - Assembled View
3.Use saw to cut opening in wall. Cut a
| inch | 8 | |
| 7 | ||
4. | Use hose clamp to secure fl ex pipe to collar assem- | ||
6 | |||
| bly. | ||
|
| ||
5. | Slide trim ring over fl ex pipe and run pipe through |
| |
|
| ||
| wall. |
| |
6. | Attach hose to outside termination cap with second | 5 | |
| hose clamp. | 4 | |
|
|
7. Secure termination cap to outside surface.
8. Secure trim ring to interior wall.
1
2
CAUTION
Never draw outside combustion air from:
• Wall, floor or ceiling cavity | Figure 19.3 |
|
•Enclosed space such as an attic or garage
3
Item | Description |
|
| 1 | Front, 3 inch |
|
| 2 | Front, 5 inch |
|
| 3 | Cast Ring, Top & Bottom, Interchangeable |
|
| 4 | Side, 5 inch |
|
| 5 | Side, 3 inch |
|
| 6 | Panel Extension, 5 inch |
|
| 7 | Panel Extension, 3 inch |
|
| 8 | Panel Extension, Base Plate Only |
Air Intake Channel |
|
|
|
(Discard) |
|
|
|
| Trim Ring | Termination |
|
|
| Cap Assembly |
|
Hose Clamp | Flex Hose |
|
|
Collar | Hose Clamp |
|
|
Assembly |
|
| |
|
|
|
Figure 19.1
August 20, 2009 | Page 19 |