R
Castile Pellet Insert
10Maintaining & Servicing Your Appliance
C. General Maintenance & Cleaning
A. Proper Shutdown Procedure | 1. Types of Fuel | ||||
|
| ||||
|
| Depending on the type of fuel you are burning will dictate how | |||
| CAUTION | ||||
| often you have to clean your fi repot. | ||||
|
| ||||
Shock and Smoke Hazard | If the fuel you are burning has a high dirt or ash content or | ||||
you are burning shelled fi eld corn, it may be necessary to | |||||
• | Turn down thermostat, let appliance completely | ||||
clean the fi repot more than once a day. | |||||
| cool and exhaust blower must be off. Now you | ||||
|
|
|
| ||
| can unplug appliance before servicing. | Dirty fuel will cause clinkers to form in the fi repot. A clinker | |||
• | Smoke spillage into room can occur if appliance | is formed when dirt, ash or a | |||
heated to 2000°F (1093°C) and becomes | |||||
| is not cool before unplugging. | ||||
|
|
|
| ||
• | Risk of shock if appliance not unplugged before | “D” page 35 in this section for more details on fuels with | |||
high ash content. |
|
| |||
| servicing appliance. |
|
| ||
|
|
|
| ||
|
|
|
|
|
Follow the detailed instructions found in this section for each step listed as referenced in the chart below.
B. Quick Reference Maintenance Chart
Clinker
Figure 31.1 - Clinker
Cleaning or Inspection | Frequency |
| Daily | Weekly | Monthly | Yearly |
|
|
|
|
|
|
|
Ash Pan
Ash Removal from Firebox
Every 5 bags of fuel | OR | |
More frequently depending on | OR | |
the fuel type or ash |
| |
|
|
X
X
Beneath Heat Exchanger Blower, Combustion (Exhaust)
Every 1 ton of fuel | OR | |
More frequently depending on | OR | |
the fuel type |
| |
|
|
X
X
Blower, Convection
More frequently depending on OR the fuel type
X
Door Latch Inspection Exhaust Path
Prior to heating season | OR | |
More frequently depending on | OR | |
ash |
| |
|
|
X
X
Firebox - Prepare for | At end of heating season | OR |
|
|
| X |
|
|
|
|
|
|
|
Firepot - Burning pellets - hardwood | Every 3 bags | OR | X |
|
|
|
|
|
|
|
|
|
|
Firepot - Burning pellets - softwood | Every 5 bags | OR | X |
|
|
|
Firepot - Burning Corn | Every 1 bag | OR | X |
|
|
|
|
|
|
|
|
|
|
Glass | When clear view of fi repot | OR |
| X |
|
|
| becomes obscure |
|
|
|
|
|
|
|
|
|
|
|
|
Heat Exchanger & Drop Tube | Every 1 ton of fuel | OR |
|
| X |
|
|
|
|
|
|
|
|
Hopper | Every 1 ton of fuel or when | OR |
|
| X |
|
| changing fuel types |
|
|
|
|
|
|
|
|
|
|
|
|
Top Vent Adapter | More frequently depending on | OR |
|
|
| X |
| the fuel type or ash |
|
|
|
|
|
|
|
|
|
|
|
|
Venting System | More frequently depending on | OR |
|
|
| X |
| the fuel type |
|
|
|
|
|
NOTICE: These are recommendations. Clean more frequently if you encounter heavy
August 20, 2009 | Page 31 |