R
Castile Pellet Insert
B. Clearance To Combustibles, UL and ULC
AS A
A | D | C |
| ||
| B | B |
C |
|
|
|
| E |
0” (0mm) Clearance To Exposed Section And Face Trim |
Figure 9.1
|
|
| Inches | Millimeters |
|
|
|
|
|
A | Top of Hopper | Top or Rear Vent | 0 | 0 |
|
|
|
|
|
B | Side of Outside Skin | Top or Rear Vent | 0 | 0 |
|
|
|
|
|
C | Back of Hopper | Top Vent | 2.5 | 64 |
|
|
|
|
|
|
| Rear Vent | 0 | 0 |
|
|
|
|
|
D | Vent Pipe to Combustible | Top or Rear Vent | 3.0 | 76 |
|
|
|
|
|
E | Front Panel Edge | Top or Rear Vent | 0 | 0 |
|
|
|
|
|
INSTALLED AS A BUILT-IN UNIT
Shown Optional Outside Air
12 in |
(305mm) |
6 in |
(153mm) |
Outside |
Air |
Figure 9.2
WARNING
Fire Risk.
Comply with all minimum clearances to combustibles as specified.
Failure to comply may cause house fi re.
NOTE:
•Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
•Illustrations/diagrams are not drawn to scale.
•Actual installation may vary due to individual design preference.
August 20, 2009 | Page 9 |