G. Prefabricated Metal Chimney
August 20, 2009
250-2061
250-2061

R

Castile Pellet Insert

G. Prefabricated Metal Chimney

The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements:

•Must be minimum 6 inch (152mm) inside diameter of high temperature chimney listed to UL 103 HT (2100oF) or ULC-S628.

•Must use components required by the manufacturer for installation.

•Must maintain clearances required by the manufacturer for installation.

•Refer to manufacturers instructions for installation

•This insert is listed to UL 1482 Standard and is approved for installation into listed factory-built zero clearance fi re- places listed to UL 127 conforming to the following speci- fi cations and instructions:

•The original factory-built clearance fi replace chimney cap must be re-installed after installing the approved chimney liner meeting type UL 103 HT requirements (2100°F) per UL 1777.

•If the chimney is not listed as meeting HT requirements, or if the factory built fi replace was tested prior to 1998, a full height listed chimney liner must be installed from the appliance fl ue collar to the chimney top.

•The liner must be securely attached to the insert fl ue collar and the chimney top.

•The air fl ow of the factory-built zero-clearance fi replace system must not be altered. The fl ue liner top support attachment must not reduce the air fl ow for the existing air-cooled chimney system.

•No dilution air is allowed to enter the chimney.

1.Secure the fi replace damper in the open position. If this cannot be accomplished, it will be necessary to remove the damper

2.Seal damper area of chimney around chimney connector with a high temperature sealant or seal insert against the face of the fi replace.

3.Both methods must be removable and replaceable for cleaning and re-installation.

H. Altering the Factory-Built Fireplace

The fireplace must not be altered, except for the exceptions listed below. Do not removal the bricks and mortar from the existing fi replace.

The following modifi cations are premissible:

Removal of damper or locked in open position

Removal of smoke shelf or baffl e

Removal of ember catches

Removel of fi re grate

Removal of view screen/curtain

Removal of doors

External trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fi replace for reassembly if the insert is removed.

The permanent metal warning label provided must be attached to the back of the fi replace, with screws or nails, stating that the fi replace may have been altered to accommodate the insert, and must be returned to original condition for use as a conventional fi replace. Figure 11.1

If the hearth extension is lower than the fi replace opening, the portion of the insert extending onto the hearth must be supported.

Manufacturer designed adjustable support kit can be ordered from your dealer.

Final approval of this installation type is contingent upon the authority having jurisdiction.

NOTE: Refer to chimney liner manufacturer for recom- mendations on supporting the liner. Installation into fi replaces without a permit will void the listing

WARNING! Risk of Fire!

Follow venting manufacturer’s clearances and instructions when installing venting system.

NOTICE: In Canada when using a factory-built chim- ney it must be safety listed, Type UL103 HT (2100oF) [1149oC] CLASS “A” or conforming to CAN/ULC-

S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.

WARNING

THIS FIREPLACE MAY HAVE BEEN ALTERED TO ACCOMMODATE AN INSERT. IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE.