| KEY DIMENSIONS | AND SPECIFICATIONS | |
Description |
| Dryer (Gas and Electric) | |
Electrical Requirements | Please refer to the rating label. | ||
Gas | Requirements* | NG: | |
Gas | Requirements* | LP: | |
Dimensions |
| 27" (W) X 28 11/16" (D) X 38" (H), 52 1/4" (D With door open) | |
|
|
| 68.60m (W) X 76.7cm (D) X 96.50m (H), 132.7cm (D With door open) |
Net Weight |
| Electric: 139 lb. (63.1kg) Gas: 142.4 lb. (64.6kg) | |
Drying Capacity |
| IEC 7.4 cu. ft. | |
*Gas | Models only. |
|
|
LOCATION REQUIREMENTS
IMPORTANT:
Read all installation instructions completely before installing and operating your dryer!
It is important that you review this entire manual before installing and using your dryer. It contains detailed instructions concerning electrical connections, gas con- nections and exhaust requirements.
I
203/20"
(56.2 cm)
CHOOSE THE PROPER | LOCATION |
|
• Store and install the dryer | where it will not be exposed | (1 |
to temperatures below freezing or exposed to outdoor |
|
weather conditions.
•Choose a location with a solid, level floor.
•If the dryer is being installed in a garage, place the dryer at least 18 in. (45.7cm) above the floor.
•Properly ground the dryer to conform with all governing codes and ordinances.
•To reduce the risk of electric shock, do not install the dryer in damp or wet locations.
IMPORTANT: | If you are | installing your | dryer in a |
| ||
manufactured | or mobile | home, | please | refer to the | 3" | |
section Special Electrical Requirements for Mobile or | ||||||
| ||||||
Manufactured | Homes on page | 12, |
| (7.6 cm) |
oL
/' / | ,, t< |
CLEARANCES
•Most installations require a minimum
(14 cm) clearance behind the dryer for the exhaust ducting.
•Allow minimum clearances of at least 1 in.
(2.5 cm) on the sides and back to minimize vibration and noise.
•Allowing additional clearance for installation and servicing is recommended.
•Be sure to allow for wall, door, or floor moldings that may increase the required clearances.
•Allow at least 21 in. (53.3 cm) in front of the dryer to open the door.
48 sq in. /
(310 cm)
io
34 sq in.
(155cm)"
i I
(7.6 cm)
(2.5 cm) | 27" | (2.5 cm) |
(68.6 cm)
1
Additional Instructions for
closet installations:
•The closet door must allow for sufficient airflow. Refer to the diagram to the left for minimum vent opening requirements. A Iouvered door is also acceptable.
Closet Door Vent
Requirements
8