Exit G-Analyzer Calibration setup mode Press the [MENU] button.
6
Start Calibration of straight direction Start moving the vehicle ahead.
Calibration of straight direction automatically starts.
When the Calibration is finished, "Calibration OK" is displayed.
• If you fail to complete the calibraton, "No Calibration" is displayed. In such a case, repeat steps 1 through 6.
5
In Standby mode
G-Analyzer Calibration setup
G-Analyzer requires calibration for horizontal acceleration and braking.
• To ensure accurate calibration, go through the following steps at a level place where you can move the vehicle straight ahead.
1 Park the vehicle in a horizontal location
2 Select G-Analyzer Calibration setup mode Push the Control knob towards [FM] or [AM]. Select the "G-Calibration" display.
3 Enter G-Analyzer Calibration setup mode Press the Control knob for at least 1 second. "Stop" is displayed.
4 Start Calibration of horizontal direction Press the Control knob.
Once "Move Forward" appears on the display, the vehicle must be advanced.

Menu system

In Standby mode

G-Counter Level set

Calibrating G-Point. Setting the level according to the kinds of vehicles.

Display

"G-Counter : Level1"

"G-Counter : Level2"

"G-Counter : Level3"

Setting

Counter is easy to go up.

Counter is hard to go up.

In the case of driving situations calling for few accelerations, set the G-Point up to "G-Counter : Level1". In the case of frequent accelerations, set it up to "G-Counter : Level3".

In Standby mode

G-Analyzer Reset

Resets the value of G-Meter, G-Counter and G- Analyzer Horsepower Analysis.

1Select G-Analyzer Reset mode

Push the Control knob towards [FM] or [AM]. Select the "G-Reset" display.

2Enter G-Analyzer Reset mode

Press the Control knob for at least 1 second.

3Select the Reset item

Push the Control knob towards [FM] or [AM]. "G-Meter Reset": Reset the value of G-Meter."G-Counter Reset": Reset the value of G-Counter."G-Power Reset": Reset the value of G-Analyzer

Horsepower Analysis.

4Reset the value

Press the Control knob for at least 2 seconds. "Reset OK" is displayed.

5Exit G-Analyzer Reset mode Press the [MENU] button.

42 English