2-l. ACCESSORIES
The following accessory items are included with the
unit. |
|
|
|
|
Instruction | manual | . l | copy | |
Fuse 2A | (AC) | .2 | pieces | |
| 7A | (DC) | .2 | pieces |
Foot | (with | screws) | .2 | pieces |
Speaker plug | .l | piece | ||
DIN | plug | .l | piece | |
AC | power | cord | . l | piece |
DC power | cord | . l | piece | |
Microphone | . l | piece |
2-2. OPERATING LOCATION
As with any solid state equipment, the
2-3. CABLING FOR ANTENNA, POWER SUPPLY AND OTHERS
430 MHz
144 MHz
L-
Ground
To prevent electric shock, TVI and BCI, select a g o o d grounding location: Con- nect the unit to the ground using a heavy earth line and an appropriate earthing rod. The earth line should be as short as possi- ble
I | Check for correct polarity | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Connection of electric key
.
Key
F o r C W O p e r a t i o n , connect the key through a phone plug. Use shielded cable.
1
Extemal speaker
A speaker is included in the unit. If you wish to use an extemal speaker, connect it by using the supplied speaker plug. A
Extemal speaker
A
Connection of speaker plug
When connecting an extemal speaker, be
type and should be as short as possible to prevent RF from being induced.
Power supply connection
The power cord has a 4P plug with a lock- i n g t a b . W h e n c o n n e c t i n g t h e Cord, squeeze the locking tab to ensure that it properly fits in place. To disconnect the Cord, squeeze the locking tab again until if is released from the locked Position.
P o w e r supply
The unit is designed to operate on AC (220 V) or DC (13.8 V). Swit- ching between AC and DC is accomplished by replacing the power cord (DC power cord is optional.) When connecting the power Cord, be sure to observe the following Points:
1.Turn off the power switch and set the standby switch to REC posi- tion.
2.When replacing the power Cord, disconnect it from the AC supply
(or battery) with care.
Failure to observe the above procedure might result in electric shock or darnage to the unit.