2.Remove 5 screws (2 each side and above GFCI) holding the metal front panel and remove panel.
screws
screws
GFCI
front panel
3.Remove terminal box screw and terminal box.
terminal box
screw
terminal
box
4.Remove power cord green ground wire from under green ground screw.
5.Remove
do not remove this
grommet
power cord
green ground wire | green ground screw |
|
6.Use pliers and squeeze locking tab in the power cord strain relief grommet.
locking tab
power cord
7.Remove power cord and grommet.
8.Install a
conduit
connector
9.Install conduit.
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector in terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
10.Route direct wire through conduit and connect wires as follows:
■Form ground wire into a hook and wrap clockwise around ground screw under washer. Tighten ground screw securely.
ground wire
direct wire
green ground
screw
■Use
11.Reinstall terminal box.
IMPORTANT: The tabs must be under the terminal box as shown.
terminal box
tabs