Enclosure Cutout Dimensions
WARNING
Fire Hazard
Do not install this side burner on or near combustible materials.
Doing so can result in death or fire.
Enclosure and clearance dimensions that are shown must be used. Given dimensions provide required clearances.
The installation of this outdoor side burner must conform with the current standards
The outdoor side burner drops into the enclosure opening and is supported by its side flanges. No bottom support is needed.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio
Gas Supply Requirements
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor” gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard National Fuel Gas Code ANSI Z223.1
12” (30.5 cm) minimum to grill or any accessory
(30.8 cm)
(5.7 cm)
(57.2 cm)
gas line
location at rear of side burner
IMPORTANT: The outdoor side burner must be connected to a regulated gas supply.
• Input ratings shown on the model/serial rating plate are for |
elevations up to 2,000 feet (610 m). For elevations above 2,000 |
feet (610 m), ratings are reduced at a rate of 4% for each 1,000 |
feet (305 m) above sea level. Orifice conversion is required. |
Contact KitchenAid Experience Center. |
• Refer to the model/serial rating plate for information on the type |
of gas that can be used. If this information does not agree with |
the type of gas available, check with your local gas supplier. |
(18.1 cm)
|
|
| ||
10- | 5/8” | |||
(90.2 cm) | ||||
(27.0 |
| cm) | ||
|
|
counter or support surfaces
must be level
No attempt shall be made to convert the outdoor side burner |
from the gas specified on the model/serial rating plate for use |
with a different gas type without consulting the serving gas |
supplier. The conversion kits specified must be used. |
L.P. GAS:
Operating pressure: 11 inches (27.9 cm) W.C.
Supply pressure: 11 to 14 inches (27.9 to 35.5 cm) W.C.
NATURAL GAS:
Set pressure: 4 inches (10.2 cm) W.C.
Supply pressure: