INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed
•Level
•Small
•
•Phillips screwdriver
•Tape measure or ruler
•
•Pipe wrench
Parts needed
•Gas line shutoff valve
•1/2” male pipe thread nipple for connection to pressure regulator
•L.P.
•CSA
•Noncorrosive leak detection solution
Parts supplied
• Convertible regulator set for 4” W.C. natural gas
WARNING
Fire Hazard
Do not use side burner near combustible materials. Do not store combustible materials near side burner. Doing so can result in death or fire.
Select a location that provides minimum exposure to wind and traffic paths. The location should be away from strong draft areas.
Do not obstruct flow of combustion and ventilation air.
WARNING
Fire Hazard
Do not install this side burner on or near combustible materials.
Doing so can result in death or fire.
Location Requirements
WARNING
Explosion Hazard
Do not store fuel tank in a garage or indoors.
Do not store side burner with fuel tank in a garage or indoors.
Failure to follow these instructions can result in death, explosion, or fire.
4
Product Dimensions
Clearance to combustible construction for
•A minimum of 12” (30.5 cm) must be maintained between the sides and back and any combustible construction.
•A 12” (30.5 cm) minimum clearance must also be maintained below the cooking surface and any combustible construction.
12” (30.5 cm)
(33.7 cm)
26” (66.0 cm)
1/2”
male NPT
(8.9 cm)