PERFORMANCE DATA SHEET
Water Filtration System
Model P6WB2L/P6RFWB2 Capacity 200 Gallons (757 Liters)
Model P6WB2NL/P6RFWB2 Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Minimum % | Average % |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
Chlorine Taste/Odor | 50% reduction | 2.0 mg/L | 2.0 mg/L ± 10% | 0.20 mg/L | 97 | 97.2 |
Particulate Class I* | 85% reduction | 7,300,000 #/mL | At least 10,000 particles/mL | 75,000 #/mL** | 99 | 99.4 |
Contaminant | NSF Reduction | Average | Influent Challenge | Maximum | Minimum % | Average % |
Reduction | Requirements | Influent | Concentration | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
Live Cysts† | 99.95% | 160,000/L | 50,000/L min. | 54/L† | 99.97 | 99.99 |
|
|
|
|
|
|
|
Asbestos | 99% | 87 MFL | 107 to 108 fibers/L†† | 0.17 MFL | 99 | 99 |
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.010 mg/L | 0.160 mg/L | 0.15 mg/L ± 10% | 0.001 mg/L | 99.4 | 99.4 |
Lead: @ pH 8.5 | 0.010 mg/L | 0.140 mg/L | 0.15 mg/L ± 10% | 0.005 mg/L | 98.6 | 98.6 |
|
|
|
|
|
|
|
Lindane | 0.0002 mg/L | 0.0019 mg/L | 0.002 mg/L ± 10% | 0.00002 mg/L | 98.9 | 99 |
|
|
|
|
|
|
|
Toxaphene | 0.003 mg/L | 0.014 mg/L | 0.015 mg/L ± 10% | 0.001 mg/L | 93 | 93 |
|
|
|
|
|
|
|
Atrazine | 0.003 mg/L | 0.0094 mg/L | 0.009 mg/L ± 10% | 0.0005 mg/L | 94.5 | 94.7 |
|
|
|
|
|
|
|
2,4 - D | 0.07 mg/L | 0.220 mg/L | 0.210 mg/L ± 10% | 0.028 mg/L | 87.5 | 96.1 |
|
|
|
|
|
|
|
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.43 gpm (1.6 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Use replacement filter P6RFWB2, part #W10413645A.
2012 suggested retail price of $39.99 U.S.A./$49.99 Canada. Prices are subject to change without notice.
Style 1 – When Order Filter is illuminated yellow, order a new filter. When Replace Filter is illuminated red, it is recommended that you replace the filter.
Style 2 – Press OPTIONS and select Filter Status to check the status of your water filter. When the filter status shows 10% remaining, order a new filter. When the filter status shows 0% remaining, it is recommended that you replace the filter.
Style 3 – Press FILTER STATUS to check the status of your water filter. When the filter status shows 10% remaining, order a new filter. When the filter status shows 0% remaining, it is recommended that you replace the filter.
■After changing the water filter, flush the water system. See “Water and Ice Dispensers” or “Water Dispenser.”
■These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.
■The product is for cold water use only.
■The water system must be installed in compliance with state and local laws and regulations.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
■Refer to the “Warranty” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8°C) |
Service Flow Rate | 0.43 gpm (1.6 Lpm) @ 60 psi |
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
†Based on the use of Cryptosporidium parvum oocysts ††Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.
38