7.Use 8” round steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 5.

Wiring to Power Supply

Manual backgroundSAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

8.Connect the electrical wires.

-Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown on Figure 6.

-If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. Make sure wires do not slip between motor or any moving parts to prevent any damage.

Install Accessories

9.Attach Oil Tunnel. Refer to Figure 7.

10.Refer to Figure 8. ￿ Slide the baffle filter into the hood. ￿ Push the baffle filter upward. ￿ Slide forward. ￿ Pull downward. ￿ Fit into place.

11.Repeat for all baffle filters and spacers. Refer to page 17.

12.Install heating lamps (not included), 120 Volts 175 Watts max. each.

Final Assembly

13.Turn power ON in control panel. Check all lights and fan operation.