Operating the Unit & Remote Control

Cleaning the Mirrors & Optical System

13.When turning the projector off, rotate the operating switch counter clockwise one step. The lamp will go off, but the fan will continue to operate. Allow the fan to operate for a few minutes to properly cool the bulb, then shut off the fan by turning the operating switch to the OFF position. Turn the power switch to the OFF position.

For added safety, your projector has a built-in fan/delay circuit. If you turn the projector completely off without cooling the lamp, the temperature probe will keep the fan running until the projector cools down.

The flat mirror in the 560 Series is aluminum coated and works as a surface reflecting mirror. In the 750 Series, there is a heat absorbing flat mirror.

Take care not to leave finger prints, stains or scratches on the surface of the elliptical mirror, the flat mirror or the Xenon bulb.

If the mirrors are smudged or stained, wipe them off gently with a lens cleaner or a piece of gauze wetted with a mixture of alcohol and ether.

Insulation Plate

Housing

Magnet Assembly

Elliptical Mirror

Xenon Bulb

Flat Mirror

Remote Control

Connect the standard Kodak Ektgraphic-IIIRemote Control to the round, 5-pin remote control socket on the rear of the projector. This will allow you to control forward/reverse and focus.

REMOTE-1 Connector (DIN 5P)

This connector is used with standard Kodak Ektagraphic-IIIRemote Controls.

1.Focus In

2.

Slide Forward

4

1

 

 

 

3.

Slide Reverse

 

5

4.

Focus Out

 

2

 

3

5.

COM

 

 

14