Slide Burning & Picture Flicker

Magnet Adjustment Solution

If the flickering problem is still apparent after readjusting the lamp position, a magnet adjustment may be needed.

1.Please follow all safety precautions listed in this manual for proper handling of the lamp. You will need to remove the top cover and operate the projector with the lamp cover off. Please note that the power interlock switch will need to be depressed in order to keep the lamp on.

2.Remove the four white screws and lift off the top cover.

3.Locate the black magnet above the reflector. If adjustment is re quired, loosen the Phillips head screw holding the magnet cylinder to the bracket.

4.While observing the illuminated screen, slowly turn the magnets until he flickering stops.

5.Retighten the screw and reinstall the lamp house cover.

The above two procedures should correct any problems you are having with burning slides and image flickering.

Insulation Plate

Housing

Magnet Assembly

Elliptical Mirror

Xenon Bulb

Flat Mirror

19