Image quality issues

 

Problem

Possible Solution

553

No print head

The check scanner may not be recognizing the ink cartridge for one of

 

 

the following reasons. Refer to the procedures in “Replacing the ink

 

 

cartridge” earlier in the chapter for proper installation procedures.

 

 

• Be sure the inkjet cartridge is properly installed.

 

 

• If it is, remove the cartridge and reseat it.

 

 

• Try installing a new inkjet cartridge.

 

 

If you have verified that the ink cartridge is installed correctly or have

 

 

replaced it, the ribbon connector may need to be reseated or the main

 

 

board may be bad.

 

 

• Contact Technical Support.

 

 

 

125

No scanner

The scanner was not found during the application to scanner

 

 

initialization.

 

 

• Check the cable and power connections to be sure the USB cable and

 

 

power supply connections are securely in place.

 

 

• Try a different USB port.

 

 

• Verify that the PC has the proper drivers and scanner firmware files

 

 

installed.

 

 

• If you have recently disconnected the USB cable from the PC, be sure

 

 

you have installed it to the same USB port or reinstall the drivers as per

 

 

the installation instructions described in Chapter 2.

 

 

NOTE: Depending on which Windows operating system you have, XP or

 

 

2000), you may need to install the drivers on all USB ports.

 

 

 

Image quality issues

Any number of image quality issues can be encountered during

 

scanning (i.e., heavy backgrounds, an image may have streaks or

 

fades, shaded lines on the rear image, etc.). Before calling Technical

 

Support, thoroughly clean your scanner using the recommended

 

cleaning procedures in the section entitled, “Weekly cleaning

 

procedures” in Chapter 4.

 

If you are experiencing skewed images, check to be sure that the entry

 

tray is fully seated.

32

A-61557 December 2006