2. Solid Wall or Stud Partition

2. Solid Wall or Stud Partition

(Using Rear Fixing Points on Shower Control)

2.1Refer to section: ‘1. Solid Wall or

Stud Partition Installation (Using Securing Brackets - Mounting off Front Face)’ and follow instructions 1 to 4.

2.2Cut away the plasterboard or brick work to the required depth.

Important! This depth ‘X’ will depend on the finished wall thickness e.g. tiles or facia board. Refer to the table for this measurement.

For stud partitions depth ‘X’ refers to the distance from the rear mounting e.g. wooden baton, to the front of the wall (before tiling).

Rear Support

Depth ‘X’

Finished Wall

Surface

Finished Wall

Thickness

Finished Wall Thickness

Wall Cutout Depth ‘X’

(e.g. tile and adhesive)

 

6 mm

76 - 58 mm

8 mm

74 - 56 mm

10 mm

72 - 54 mm

 

 

12 mm

70 - 54 mm

14 mm

68 - 54 mm

 

 

16 mm

66 - 54 mm

 

 

18 mm

64 - 54 mm

20 mm

62 - 54 mm

22 mm

60 - 54 mm

24 mm

58 - 54 mm

 

 