Reversed Supplies

Reversed Supplies

The Discovery Dual Control is supplied with inlet connections Hot-Left, Cold-Rightand Top-Outletas standard. If the hot and cold water supply pipes have been reversed during installation the following procedure must be performed.

Note! Refer to illustrations in section: ‘Installation, Control Assembly’.

1. Isolate the hot and cold water supplies.

2. Pull off the temperature knob.

3. Unclip and remove the concealing plate.

Note! Use a screwdriver in the slot at the bottom of the concealing plate to lever off.

‘O’ Key

4. Fit the ‘O’ Key (supplied) onto the cartridge nut and turn anticlockwise. Unscrew and pull the cartridge clear from the body.

Note! Depending on the finished wall thickness it may be necessary to remove the backplate.

5.Rotate the cartridge 180°.

6.Make sure that the two cartridge side seals are fitted and carefully push into the cartridge body.

Important! Make sure that the cartridge side seals do not extrude from the body when pushing the cartridge in. Damage to these seals may result in incorrect operation.

7.Position the cartridge lugs into the body slots and tighten the nut by turning the ‘O’ Key clockwise.

8.Restore the hot and cold water supplies and check for leaks.

9.Refer to section: ‘Installation, Control Assembly’ and follow instructions 3 to 9.