MAINTENANCE

General

This Product is precision engineered and should give continued safe and controlled performance, provided:

1.It is installed, commissioned, operated and maintained in accordance with manufacturers recommendations.

2.Periodic attention is given, when necessary, to maintain the product in good functional order.

Lubricants

Silicone-only based lubricants can be used to assist in refitting.

Caution! Oil based or other lubricant types, may cause rapid deterioration of seals.

Cleaning

Warning! Many household cleaners contain abrasive and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned using a mild washing up detergent or soap solution, rinsed and then wiped dry with a soft cloth.

Filters

1.Isolate the supplies to the shower control and operate the flow control to drain any residual water.

2.Unclip and remove the concealing plate.

3.Unscrew the 3 backplate securing screws and remove the backplate.

4.Unscrew the filter caps with the ‘O Key’ (supplied) or a 12 mm hexagonal wrench and remove the filters.

5.Clean each filter in turn under a jet of water to remove any lodged particles.

6.Re-fit the filters and tighten the filter caps.

7.Restore the water supplies and check for leaks.

8.Reassemble the shower control (refer to section ‘Installation, Control Assembly’.

Supply Filter

‘O’ Key

25

Page 25
Image 25
Kohler Discovery manual Maintenance, Lubricants, Cleaning Filters