FAULT DIAGNOSIS

FAULT DIAGNOSIS

 

SYMPTOM

 

CAUSE/RECTIFICATION

 

 

 

1. Only hot or cold

a.

Inlets reversed (hot supply to cold supply).

 

water from the control

 

Refer to section: ‘Reversed Supplies’.

 

outlet.

b.

No hot water reaching the control.

 

 

c.

Check the filters for any blockage.

 

 

d.

Installation conditions outside operating

 

 

 

parameters: refer to sections: ‘Specifications’

 

 

 

and ‘Commissioning’.

2.

Fluctuating or reduced

a.

Check the showerhead, hose and filters for any

 

flow rate.

 

blockage.

 

 

b.

Make sure minimum flow rate is sufficient for

 

 

 

supply conditions.

 

 

c.

Make sure the maintained inlet pressures are

 

 

 

nominally balanced and sufficient.

 

 

d.

Make sure the inlet temperature differentials are

 

 

 

sufficient.

 

 

e.

Check the thermostatic performance.

 

 

f.

Flow regulator fitted incorrectly.Refer to Note below.

 

 

g.

Airlock or partial blockage in pipework.

 

 

 

3. No flow rate from the

a.

Check the showerhead, hose and filters for any

 

control outlet.

 

blockage.

 

 

b.

Hot or cold supply failure.

4.

Blend temperature drift.

a.

Refer to symptom 2. above.

 

 

b.

Hot supply temperature fluctuation.

 

 

c.

Supply pressures fluctuating.

 

 

d.

Seal damage or wear. Renew the thermostatic

 

 

 

cartridge.

5.

Maximum blend

a.

Indicates incorrect maximum temperature

 

temperature setting

 

setting; refer to section: ‘Commissioning’.

 

too hot or too cold.

b.

Refer to symptom 4. above.

6. Water leaking from the

a.

Normal for a short period after shut off.

 

shower control fitting.

b.

Check that the pressures are not in excess of

 

 

 

the for product.

 

 

c.

Renew the flow cartridge.

7. Flow rate too low or

a.

(Too low) Insufficient supply pressures.

 

too high.

b.

(Too low) Refer to symptom 2. above.

 

 

c.

(Too high) Supply pressure too high. Install

 

 

 

supplied flow regulator on the outlet.Refer to Note below.

 

 

d.

(Too high) Refer to symptom 2. above.

Note! Refer to the Discovery Fittings Installation and User Guide.