Problem

Inaccurate exposures with very bright or dark scenes.

Anti-Shake

does not

work.

Symptom

Shutter speed and/or aperture display blink.

Arrows blink at

each end of the Ev scale.

The viewfinder

Anti-Shake

scale is blinking.

Cause

Subject or scene is outside the exposure control range of the camera.

Subject or scene is outside the metering range of the camera.

CCD setup error.

Solution

Adjust the exposure until the

display stops blinking

or change camera sensitivity

(p. 54).

In dark conditions, use the camera flash. Under bright light, use a neutral density filter on the lens to control the light levels.

Turn the camera off and on. If

the Anti-Shake scale

continues to blink, contact a Konica Minolta service facility.

Unable to see

recorded images in playback.

Folder number not displayed.

Folder is not selected

Select the folder with the

with the view-folder

menu (p. 82).

option in section 1 of the

 

playback menu.

 

Unable to delete folders with

Memory card was

Delete the folder using the

opened on a Windows

the file browser (p. 87).

computer.

operating system.

 

 

If the camera does not function normally, turn it off, remove and reinsert the battery, or unplug and reconnect the AC adapter. Always turn the camera off using the main switch otherwise the memory card may be damaged and camera settings reset.

138TROUBLESHOOTING