La Pavoni P180 manual Installation, Electric Connection

Models: P180

1 16
Download 16 pages 59.05 Kb
Page 4
Image 4

INSTALLATION

Before installing the machine, read carefully the manual.

The installation site must be level and dry.

ELECTRIC CONNECTION

Before connecting the machine to an electric plug, please follow these precau- tions:

oThe main supply must be suitable for the machine power requirements

(1600W).

oCheck that the power supply voltage is the same as the one shown in the

rating label.

oCheck that the main socket is correctly earthed.

oIf the power supply cable is to be replaced, use only original cables.

The manufacturer will not accept responsibility for any damage claiming if these precautions are not complied with.

The machine is provided with a general lighted switch, located on the back panel, and with a security push button on the chassis that will cut off the power to the electronic board when you open the door.

If you want to restore the power when the door is open, take out the push button.

All the machine electric devices work with a 24 VDC voltage, except for boiler heating element and the transformer that work with 230 or 115 VAC.

LEGEND

F

WATER FILTER

VA

ONE-WAY VALVE

DLIMESTONE FILTER (OPTIONAL) CV FLOWMETER

P PUMP

VVALVOLA NON RITORNO

C BOILER

EV1 TEA ELECTROVALVE

EV2

MILK & CHOCOLATE ELECTROVALVE

EV3

NOT AVAILABLE

EVE

ESPRESSO ELECTROVALVE

GE

ESPRESSO BREWER

M1

TEA MIXING GROUP

M2

MILK & CHOCOLATE MIXING GROUP

S

WASTE

U1

TEA OUTLET

U2

MILK & CHOCOLATE OUTLET

U3

NOT AVAILABLE

UC

ESPRESSO OUTLET

Pag. 4

Pag. 29

Page 4
Image 4
La Pavoni P180 manual Installation, Electric Connection