Choosing the Clock Types to Synchronize

To select a clock type for the master clock to synchronize, use the [2]=SELECT CLOCK CTL function. This allows you to match the master clock to the type of secondary clocks installed. This function configures both clock #1 (relays 7 and 8) and clock #2 (relays 5 and 6), if present.

Notes:

To check the current master clock configuration, use the quick command [*] while the clock is in clock mode. The CLK1 and CLK2 clock type code numbers appear in the fourth line of the display. (See Appendix B for a list of the clock codes.)

If the master clock will synchronize Dukane digital clocks, verify that relay 7 has been replaced with the solid-state relays available in the Dukane kit #438-860. Then assign code 07 to CLK1.

Enter the administrative password as shown on page 2-2,then follow the key sequences below:

PressDisplay

[#]SELECT FUNCTION CODE

[2][2]=SELECT CLOCK CTL

[#]ENABLE CLOCK CIRCUIT SELECT CLK1 CODE: NN [#] FOR CODE LIST

 

Refer to Appendix B, or press [#] repeatedly to scroll the code list.

[0]...[9]

Enter the two-digit code for CLK1, then press [#]. If you will not use

 

a CLK1, enter 00.

[#]CLK TYPE CODE: NN

If you chose a CLK1 type other than 00, you will see:

SELECT CLK2 CODE: NN

[0]...[9]

Enter the code for CLK2, or 00 if you will not use a CLK2.

[#]PRESS [#] IF CORRECT

[#]Press [#] to accept, or [*] to cancel and try again.

24A715/24A715M Master Clock Installation Manual

2-5