To select a clock type for the master clock to synchronize, use the [2]=SELECT CLOCK CTL function. This allows you to match the master clock to the type of secondary clocks installed. This function configures both clock #1 (relays 7 and 8) and clock #2 (relays 5 and 6), if present.
Notes:
To check the current master clock configuration, use the quick command [*] while the clock is in clock mode. The CLK1 and CLK2 clock type code numbers appear in the fourth line of the display. (See Appendix B for a list of the clock codes.)
If the master clock will synchronize Dukane digital clocks, verify that relay 7 has been replaced with the
Enter the administrative password as shown on page
PressDisplay
[#]SELECT FUNCTION CODE
[2][2]=SELECT CLOCK CTL
[#]ENABLE CLOCK CIRCUIT SELECT CLK1 CODE: NN [#] FOR CODE LIST
| Refer to Appendix B, or press [#] repeatedly to scroll the code list. |
[0]...[9] | Enter the |
| a CLK1, enter 00. |
[#]CLK TYPE CODE: NN
If you chose a CLK1 type other than 00, you will see:
SELECT CLK2 CODE: NN
[0]...[9] | Enter the code for CLK2, or 00 if you will not use a CLK2. |
[#]PRESS [#] IF CORRECT
[#]Press [#] to accept, or [*] to cancel and try again.
24A715/24A715M Master Clock Installation Manual |