For a list of Type 07 clocks, see the chart on the first page of this appendix.
Dukane digital clocks MUST be connected to CLK1 (relays 7 and 8) on the master clock. Also, for the master clock to operate Dukane Digital clocks, its
from Dukane in the Model
Notes:
Dukane Model 24D20 and 24D40 are only used with 15Vdc power when being added to existing installations. In new installations, these two models should be used with 24Vac power.
See the 24D20 and 24D40 installation manuals (document numbers
During normal operation the clock signal is grounded once every minute at zero seconds (HH:MM:00) to increment the time display. Once every 24 hours the master clock synchronizes all clocks to 12:00:00 AM.
The master clock automatically synchronizes the clocks after a power failure or when the master time is reset. During synchronization the clocks reset, then after 40 seconds the master clock slowly advances the clocks to the correct time. The clocks can be manually reset using the [9]=SYNCH. CLOCKS function (see page
24A715/24A715M Master Clock Installation Manual |