There are two kinds of Type 02 secondary clocks: the
Note:
For a list of Type 02 clocks, see the chart on the first page of this appendix.
Every minute, from the 58th second to 00 seconds, a 24Vdc pulse is transmitted to the secondary clocks. From the 59th minute through the 49th minute, the pulse is transmitted with line AB positive with respect to PC. From the 50th minute to the 59th minute, the pulse is transmitted with line AB negative with respect to PC. Clocks that reach the 59th minute ahead of the master clock stop, since at this time they respond only to pulses transmitted with line AB positive with respect to PC.
During the 59th minute, from 10 seconds through the 50th second, 20 rapid pulses are transmitted at 0.5Hz to advance all slow clocks. During the rapid pulsing, line AB is negative with respect to PC. Connect a diode as shown in Figure
An accumulator, designed in the software, counts the number of minutes lost due to power failure. When power is restored, the master clock transmits pulses with line AB positive with respect to PC to immediately advance the slow clocks to the proper time. Resetting the time after a power failure terminates these correction signals.
Manual clock advances and daylight saving advances cause the master clock to transmit 62 pulses (1 second ON and 1 second OFF at 0.5Hz). The first five pulses are transmitted with line AB positive with respect to line PC. The remainder of the pulses are transmitted with line AB negative with respect to line PC. Normal minute pulses are inhibited during these pulses.
X = Normally open contact
I = Normally closed contact
1 = V250LA4 MOV or equal |
|
|
|
|
|
|
|
|
2 = 1N4004 diode or equal |
|
|
| RELAY |
|
|
| |
RELAY |
|
| K5 (K7) |
|
|
| ||
K6 (K8) |
|
|
|
|
|
|
| |
| x |
| I |
|
| I |
|
|
|
|
| x |
|
| x |
|
|
CLK1 OR CLK2 |
|
|
|
|
|
|
| MASTER CLOCK |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | FIELD CONNECTIONS |
|
|
|
|
|
|
|
| |
|
|
|
|
| 1 |
|
| AB |
10 ASB MAX. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
– |
|
|
|
|
|
|
| PC |
| 2 |
|
|
|
|
|
| |
+ |
|
|
|
|
|
|
|
|
Figure
24A715/24A715M Master Clock Installation Manual |