COMPONENT DEFINITIONS
•Air Wash
A small slot in the door that allows room air to be pulled into the firebox and pours over the inside surface of the door glass to inhibit the build up of soot.
•Auger
A motor powered screw device that transfers the fuel from the hopper to the feed chute to deliver pellets to the UltraGrate™.
•Auger Motor
Drives the Auger. Motor specifications are: 0.5 Amp, 1.25 RPM (revolutions per minute).
•Blower, Room Air (Convection)
The blower function is to transfer the heat from the appliance to heat the room air.
•Blower, Exhaust (Combustion)
It has a radial impeller to deliver more air to the UltraGrate™. It pulls air into the UltraGrate by creating a negative pressure. This is done by extracting the exhaust gases out of the firebox and pushing the exhaust downstream to the flue exit.
•Thermal Switches, High Limit
There are three of these
-Auto Reset Thermal Snap Switch for Room Air Blower (L250- 30F, N/C*) – This switch will trip at 250° F and will automatically reset when it reaches a temperature of 220° F. This switch is located on the room air blower jacket and is designed to detect an overfire condition.
-Auto Reset Thermal Snap Switch for Combustion Air Inlet
-Manual Reset Thermal Snap Switch for Feed Chute
•Thermal Switch, Low Limit (Ceramic,
•Hopper Lid Switch
It is located on the left hinge area inside the hopper. It detects whether the hopper lid is open and will turn off the auger motor if the hopper lid is not properly closed. When opening the hopper when refueling, do not allow the hopper lid to remain open too long or the fire may extinguish. NEVER DISCONNECT OR BYPASS THIS SWITCH FOR
ANY REASON.
•Hopper
The hopper is where the pellets are stored.
•Heat Output Button
It controls power to the feed system - auger motor and combustion blower. Use the heat output button to adjust to any of the five feed rate settings (which controls the burn rate).
•Pressure Switch
A safety device used to shut off the feed system (auger motor) if there is too much back pressure in venting system. Some possible causes are as follows:
• The venting system is obstructed.
• High altitude or other misc. environmental conditions affecting exhaust flow.
• Improper venting system.
The Pressure Switch is located inside the right access door right next to the combustion blower.
•UltraGrate (Burn Grate)
This is where combustion occurs and may be referred to as the “Burn Grate”.
*N/C = Normally Closed N/O = Normally Open
YEL YEL |
|
|
THERMOSTAT CONNECTOR |
| |
|
| |
2 | 4 | 6 |
HOPPER | PRESSURE | |||
RESETTABLE | LID SWITCH | SWITCH | ||
SWITCH N/C | SWITCH N/C | N/C | N/C | SWITCH N/C |
ABOVE ROOM | ON AUGER | LEFT HOPPER | INSIDE RIGHT | DIRECTLY |
AIR BLOWER | TUBE | LID HINGE | ACCESS DOOR | ABOVE |
|
| AREA |
| ASHPAN |
AUGER MOTOR
Montage TM 32FS
Wire Diagram
NOTE: SWITCH CONDITIONS GIVEN AT ROOM TEMPERATURE, STOVE OFF
POWER DISCONNECT |
|
|
|
L | 1 | 3 | 5 |
J P
CONV
N/C = NORMALLY CLOSED N/O = NORMALLY OPEN
| HOT |
|
| ||
| GND |
| 4 | 3 | |
N | NEUT | ||||
|
| ||||
|
| GRN | 2 | 1 | |
|
|
| |||
P/N |
|
|
IGNITER FUSE
IGNITER
ON COMBUSTION BLOWER HOUSING
J P
BLOWER
COMB
BLOWER
J = JACK
P = PLUG
= FEMALE DISCONNECT
= MALE DISCONNECT = STUD CONNECTION
IGN
Figure 35 - WIRING DIAGRAM 120 V AC
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
27