Lennox Hearth operation manual Clearances, Montage 32FS

Models: 32FS

1 36
Download 36 pages 24.37 Kb
Page 5
Image 5
CLEARANCES

Up to * 6” (153 mm)

Rear

6”

 

6”

(153 mm)

Top View

(153 mm)

min.

 

min.

Front

Floor Protector

6” (153 mm) min.

*Note: When installed at clearances less than 6”, the floor protection is only required to extend to the wall.

Figure 1 - Floor Protection Requirements

CLEARANCES

Standard residential or manufactured home installation. These appliances require the following minimum clearances to combustibles:

Minimum Clearances To Combustibles

Montage 32FS

Horizontal Flue –

Interior Vertical

 

Directly Through Wall

Flue

A - Side wall to unit

u 4” (102 mm)

u 4” (102 mm)

B - Back wall to unit

2” (51 mm)

9” (229 mm)

 

 

 

C - Side wall to unit Corner

1” (25 mm)

1” (25 mm)

 

 

 

D - Max. Depth of Alcove

v 24” (610 mm)

v 24” (610 mm)

 

 

 

E - Flue to Wall

3” (77 mm)

3” (77 mm)

 

 

 

u Measured to fuel hopper lid in alcove.

v Minimum Alcove Measurements - Height 48” (1220 mm) x Width 31” (788 mm) x Maximum Depth 24” (610 mm)

Table 1 - Minimum Clearances To Combustibles

 

 

Rear Wall or Alcove

 

 

 

 

Combustible

 

 

 

B

E

 

D

Combustible

 

 

Combustible

 

A

A

 

 

 

Figure 2

 

 

 

 

 

 

Corner

 

 

 

 

Combustible

 

 

 

E

C

 

 

 

C

 

 

 

Combustible

 

 

 

Figure 3

Montage 32FS IMPORTANT

Minimum clearances specified may not allow for ease of operation and maintenance (please take this in to account when planning the instal- lation). If installed to the minimum clearances, removal of the appliance may be necessary for servicing.

Recommended clearance zone from the front of the appliance to combustibles is 4 feet mini- mum.

Clearances to combustibles for the appliance can only be reduced by means approved by the regulatory authority.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE