Lennox Hearth 32FS Damper Location, Installation And Adjustment, Damper Adjustment

Models: 32FS

1 36
Download 36 pages 24.37 Kb
Page 9
Image 9
Prior to lighting your appliance:

Prior to lighting your appliance:

qReview the safety precautions section.

qReview the pellet FUEL section.

qReview and follow the Operating Instructions.

qPlug power cord connector into corresponding connector on the back of appliance (see Figures 7 and 8 showing connector locations).

After you have begun operation of your appliance:

qReview the routine cleaning / maintenance information.

qEnjoy the warmth from your new Lennox Hearth Products pellet stove!

Damper Location, Installation And Adjustment

Damper Air Control

Located behind the right side panel on model Montage 32FS.

Adjustment Procedure

Using a 1/4" nut driver or socket, loosen the damper setscrew (see Figure 6). Adjust in 1/4” increments until optimum combustion air flow is achieved. Retighten the damper setscrew.

For less air push in and for more air pull out.

Loosen Setscrew

Standard Settingto Adjust Damper 3/4" (19mm)

Damper

Figure 6 - Damper Adjustment

IMPORTANT NOTE: Install the thermostat per the manufacturers instruc- tions, provided with the thermostat. Failure to follow manufacturers instructions could result in a malfunction. Pay special attention to the thermostat location requirements. If the location requirements are not adhered to the appliance, erratic operation or failure may occur.

Do not mount the thermostat where it may be affected by:

Radiant heat from the stove, fireplaces, sun or other heat sources.

Drafts or dead spots behind doors or in corners.

Hot or cold air from ducts.

Thermostat Installation:

Note: Always Disconnect Power Before Performing The Thermostat Installation.

A 24 volt wall thermostat and 20 feet of 18-gage thermostat wire is included in the accessory package. It is recommended that the thermostat and thermostat wire be installed by an Lennox Hearth Products dealer.

Thermostat wires and purple wires from wire har- ness will connect to these 2 terminals

Jumper

Route thermostat wires

Remove jumper if Thermostat IS to be used

through this grommet

Leave jumper on, if thermostat is NOT used

 

Figure 7 - Terminal Block

Installation Steps:

1.Unplug stove power cord from the wall outlet.

2.Locate the thermostat terminal block (see Figures 7 and 8).

3.Loosen the two terminal screws on the terminal block and remove the jumper.

4.Connect the two wires from your thermostat to the terminals (one per terminal). Ensure that the purple wires from the harness remain connected to the terminal block and tighten the terminal screws. Make sure the wires are firmly connected to the thermostat.

5.Plug in the stove and you are ready to operate with your thermo- stat!

Note: See Wiring Diagram on Page 27.

After you have begun operation of your appliance: IMPORTANT

If the wall thermostat provided is not used, the jumper is required for the stove to operate.

Figure 8 - Terminal Block Location

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Page 9
Image 9
Lennox Hearth 32FS Damper Location, Installation And Adjustment, Damper Adjustment, Prior to lighting your appliance