Lennox Hearth 32FS operation manual G = Clearance to inside corner *min. 12”/30cm, Vent Terminal

Models: 32FS

1 36
Download 36 pages 24.37 Kb
Page 11
Image 11
Vent Termination Locations

Vent Termination Locations

Air Supply Inlet

Vent Terminal

Area Where Terminal Is Not Permitted

Vertical Terminal

Vertical Terminal

24”

(610mm)

(From Eave)

24”

(610mm)

DVent Terminal

E

M

H

 

B

 

F

 

J

G Area Where Terminal Is Not Permitted

A

Vertical TerminalFixed Closed

B (From Eave) B

CG G = Clearance to inside corner *(min. 12”/30cm)Manual background N

Manual backgroundB

Manual background K Manual background

Manual backgroundA

B

Able To Open

L

A = Clearance above grade, veranda, porch, deck, or bal- cony (min. 12”/30cm)

B = Clearance to window or door that may be opened (min. 12”/30cm above - 48”/1.2m below and to the side)

C = Clearance to permanently closed window *(min. 12”/30cm)

D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of *(min. 24”/60cm) from the centerline of the terminal (min. 22”/55cm) check with local code.

E = Clearance to unventilated soffit *(min. 12”/30cm) F = Clearance to outside corner *(min. 12”/30cm)

G = Clearance to inside corner *(min. 12”/30cm)

H = Not to be installed above a meter/regulator assembly within *(min. 36”/90cm) horizontally from the center- line of the regulator.

J = Clearance to service regulator vent outlet *(min. 72”/1.8m)

K = Clearance to non-mechanical air supply inlet to build- ing or the combustion air inlet to any other appliance *(min. 48”/1.2m)

Figure 9

L = Clearance to a mechanical air supply inlet *(min. 120”/3.1m)

M = **Clearance above paved sidewalk or a paved driveway located on public property *(min. 84”/2.1m)

N = ***Clearance under veranda, porch, deck, or balcony (min. 12”/30cm)

Note:

*Local codes or regulations may require different clear- ances.

**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE