HORIZONTAL VENT FIGURES/TABLES (CONTINUED)

 

**Wall

 

Firestop/Spacer

 

H

H1

V*

 

***Note - When using

 

Secure Flex, use

**Wall

Firestop/Spacer SF4.5VF

Firestop/Spacer

 

TABLE D

H + H1 Maximum

V Minimum

feet

(meters)

feet

(meters)

 

 

 

 

5

(1.524)

1

(0.305)

 

 

 

 

10

(3.048)

2

(0.610)

 

 

 

 

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

**Use Firestop/Spacer SV4.5HF or SF4.5HF when using Secure Vent or Secure Flex respectively. Use Firestop/Spacer SV4.5HF5 or SF4.5HF5 when using Secure Vent or Secure Flex on horizontal vent runs for the MPLDV35/40/45 with a center line lower than 48” (1219 mm) above the fireplace top wrapper surface. In all cases the firestop/spacer provided with the termination may be used with the termination, frame to 5” clearance where applicable.

***Ceiling

Firestop/Spacer

(SV4.5VF)

Support Bracket

*To Top Surface Of

Fireplace

V + H + H1 = 40 feet (12.2 m) Max.

H+ H1 = 20 ft. (6.096 m) Max.

Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required.

This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of (V) vertical, you are allowed 5

Square termination (SV4.5HT-2) shown.

See Table 3 on page 18 as an aid in venting component selection for a particular range of exterior wall thicknesses.

feet of (H) horizontal run, up to a maximum horizontal run of 20 feet.

Figure 32 - Top Vent - TWO 90 DEGREE ELBOWS - ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE

H1

***Wall

Firestop/Spacer

V1

**When using Secure Flex, use Firestop/Spacer SF4.5VF

**Ceiling

Firestop/Spacer

(SV4.5VF)

H

TABLE E

H + H1 Maximum

V + V1 Minimum

feet

 

(meters)

feet

(meters)

 

 

 

 

 

5

 

(1.524)

1

(0.305)

10

 

(3.048)

2

(0.610)

15

 

(4.572)

3

(0.914)

20

 

(6.096)

4

(1.219)

 

H + H1 = 20 feet (6.096 m) Max.

V + V1+ H + H1 = 40 ft. (12.192 m) Max.

***Use Firestop/Spacer SV4.5HF or SF4.5HF when using Secure Vent or Secure Flex respectively. Use Firestop/Spacer SV4.5HF5 or SF4.5HF5 when using Secure Vent or Secure Flex on horizontal vent runs for the MPLDV35/40/45 with a center line lower than 48” (1219 mm) above the fireplace top wrapper surface. In all cases the firestop/spacer provided with the termination may be used with the termination, frame to 5” clearance where applicable.

**Ceiling

***Wall Firestop/Spacer

Firestop/Spacer (SV4.5VF)

Support Bracket

*To Top Surface

Of Fireplace

V*

Example: If 20 feet of (H) horizontal vent run is needed, then 4 feet minimum of (V) vertical vent will be required.

This table shows a 1 (V) to 5 (H) ratio. For every 1 foot of (V) vertical, you are allowed 5 feet of (H) horizontal run, up to a maxi- mum horizontal run of 20 feet.

20

Square termination (SV4.5HT-2) shown.

See Table 3 on page 18 as an aid in venting component selection for a particular range of exterior wall thicknesses.

Figure 33 - Top Vent - THREE 90 DEGREE ELBOWS - ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Page 20
Image 20
Lennox Hearth EN54-VDLPM, MN04-VDLPM, MN03-VDLPM, MP54-VDLPM, MP03-VDLPM, MP04-VDLPM Wall, Ceiling Firestop/Spacer SV4.5VF