FIREPLACE FRAMING SPECIFICATIONS

Framing should be constructed of 2 x 4 or larger lumber.

BD

C

1/2 A

A

Inches (mm)

Figure 9

Framing

10-1/2

 

 

 

 

Model No.

 

A

B

C

D

(267)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPLDV30

in.

30 9/16

40 3/4

16 1/2

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

786

1035

419

965

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in.

35 9/16

40 3/4

16 1/2

38

 

 

*7

 

MPLDV35

 

 

 

 

 

 

 

 

5-1/8

(178)

 

mm

903

1035

419

965

 

 

**12-1/8

 

(130)

 

 

 

in.

40 9/16

45 3/4

16 1/2

43

 

 

 

 

(308)

MPLDV40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

1030

1162

419

1092

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPLDV45

in.

45 9/16

45 3/4

16 1/2

43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

1157

1162

419

1092

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*9" (229 mm) For MPLDV-35, 40 & 45 **14-1/8" (359 mm) For MPLDV-35, 40 & 45

C is the required framing depth

dimension when the finish material (drywall) thickness is 1/2 in. (13mm).

Model No.

 

A

B

C

D

E

 

 

 

 

 

 

 

MPLDV30

in.

30 1/4

52 1/4

37

14 7/64

26 1/8

 

 

 

 

 

 

mm

768

1327

940

358

664

 

 

 

 

 

 

 

 

MPLDV35

in.

 

 

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPLDV40

in.

40 1/4

62 1/4

44

17 5/8

31 1/8

 

 

 

 

 

 

mm

1022

1581

1118

448

791

 

 

 

 

 

 

 

 

MPLDV45

in.

 

 

 

 

 

 

 

 

 

 

 

mm

 

 

 

 

 

 

 

 

 

 

 

Note: The appliance 45° collar can be rotated about its axis to align for corner installation. Remove interfering corner spacer. This spacer is used for shipping only.

b

*D

7 (178)

May Be

*C

May Be

 

Removed

a

Removed

*E

A

*B

Back wall of chase/enclosure (including any finishing materials)

8

Note-

*These dimensions occur when one 45 degree elbow

Inches

Venting requirements for corner installations - the horizontal vent length

“a” to “b,” must not exceed 28 inches (711 mm)

is connected directly to the appliance collar.

(millimeters)

Figure 10 Corner Framing with Square Termination (SV4.5HT-2)

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Page 8
Image 8
Lennox Hearth EN54-VDLPM Model No, 903 1035 419 965, 1030 1162 419 1092, Framing, Is the required framing depth