Vent Parts List
Direct vent pipe Security™ Secure Vent™ * may be used with the Vintage™ gas stove. Please see the lists below to verify the components available from each direct vent pipe manufacturer. Snorkel terminations are available for applications which may require vertical rise on the building exterior. The components listed below come in a galvanized finish. Most of the components are also available in a painted black finish. Add a “B” to the end of the part number when ordering if a black part is desired.
Security™ Secure Vent 6-5/8”x 4” Pipe
Part Number | Description |
SV4LC | 6” Pipe Length |
SV4L12 | 12” Pipe Length |
SV4L24 | 24” Pipe Length |
SV4L36 | 36” Pipe Length |
SV4L48 | 48” Pipe Length |
SV4LA | 6” Pipe, Adjustable |
SV4LA12 12” Pipe, Adjustable | |
SV4FA | Flashing, 1/12 to 6/12 Roof Pitch |
SV4FB | Flashing, 7/12 to 12/12 Roof Pitch |
SV4RSM | Wall Radiation Shield |
SV4E46 | 45º Elbow |
SV4E90 | 90º Elbow |
SV4VS | Vinyl Shield Protector |
SV4FC | Storm Collar |
SV4CGV | Vertical Termination Cap |
SV4BF | Firestop |
SV4CHC | Horizontal Termination Cap |
SV4STC36 | Snorkel Termination Cap (36”) |
SV4STC14 | Snorkel Termination Cap (14”) |
SV4BM | Wall Band |
Simpson | |
Part Number | Description |
908 | 6” Pipe Length |
907 | 9” Pipe Length |
906 | 12” Pipe Length |
904 | 24” Pipe Length |
903 | 36” Pipe Length |
902 | 48” Pipe Length |
911 | 11” to |
942 | Wall Thimble |
940 | Rnd Support Box/Wall Thimble Cover |
941 | Cathedral Ceiling Support Box |
943 | Flashing, 0/12 to 6/12 Roof Pitch |
943S | Flashing, 7/12 to 12/12 Roof Pitch |
945 | 45º Elbow |
990 | 90º Elbow |
950 | Vinyl Siding Standoff |
953 | Storm Collar |
963 | Ceiling Firestop |
988 | Wall Strap |
981 | Snorkel Termination (36”) |
982 | Snorkel Termination (14”) |
984 | Horizontal Termination Cap |
985 | Horizontal Termination Cap (High Wind) |
980 | Vertical Termination Cap |
991 | Vertical Termination Cap (High Wind) |
Horizontal Vent Installation
Venting terminals may not be recessed into a wall or siding.
1.Set the unit in the desired location. Check whether or not wall studs are in the way when the venting system is attached. If wall studs are in the way, you may want to adjust the location of the unit.
2.Any stove that is horizontally terminated and has a vertical section of pipe off the top of the stove, that first section of pipe must be a minimum of 18” long.
3.All horizontally terminated vent installations may only use
4.Assemble the desired combination of pipe and elbow(s) to the appli- ance adapter with pipe seams facing down. Offsetting the pipe seams as double seams in one place will cause the outer pipe to take an oval shape.
5.When this pipe passes through a wall, a wall thimble - Simpson #942 or Security™ #SV4RSM - is required. The hole in the wall for the wall thimble should be
6.Horizontal runs of vent pipe must be supported every 3 feet. Wall straps - Simpson #988 or Security™ #SV4BM - are available for this purpose.
7.If the vent passes through a ceiling or floor, a firestop - Simpson #963 or Security™ #SV4BF - is required.
8.Also note that venting terminals shall not be recessed into a wall or siding. If installing the termination cap on a wall covered with vinyl siding, a vinyl siding standoff - Simpson #950 or Security™ #SV4VS - or furring strips must be used to ensure that the termination cap is not recessed into the siding.
9.The horizontal run of vent should have a 1/4” rise for every 12” of run toward the termination. Never allow the vent to run downward. This
could cause high temperatures and may present the possibility of a fire.
10.If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, an 7” diameter hole is acceptable and a wall thimble is not required..
11.The location of the horizontal vent termination on an exterior wall must meet all local and national building codes and must not be blocked or obstructed. For allowable external vent termination locations (see Page 15).
12.Allowable clearances from the vent pipe to combustible materials must be maintained. See Page 6 for these clearances.
13.Do not locate the termination cap where it may be blocked by shrub- bery or snow.
* Other approved chimney brand is Simpson
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.