Lenovo 1048, 1046, 1047, 1045 manual Power problems

Models: 1048 1045 1046 1047

1 140
Download 140 pages 10.44 Kb
Page 111
Image 111

Symptom

Action

 

 

 

 

3.

Replace the device that you just installed.

 

 

A Lenovo optional device that

1. Make sure that all of the hardware and cable connections for the device are

used to work does not work

 

secure.

now.

2.

If the device comes with test instructions, use those instructions to test the

 

 

 

device.

 

3.

If the failing device is an SCSI device, make sure that:

 

 

• The cables for all external SCSI devices are connected correctly.

 

 

• The last device in each SCSI chain, or the end of the SCSI cable, is

 

 

terminated correctly.

 

 

• Any external SCSI device is turned on. You must turn on an external SCSI

 

 

device before you turn on the server.

 

4.

Reseat the failing device.

 

5.

Replace the failing device.

 

 

 

Power problems

Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs).

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

The power-control button does

1. Make sure that the power-control button is working correctly:

not work (the server does not

a. Disconnect the server power cords.

start).

b. Reconnect the power cords.

Note: The power-control

button will not function until

c. (Trained service technician only) Reseat the operator information panel

3 minutes after the server has

cables, and then disconnect the server power cords. Reconnect the power

been connected to ac power.

cords. If the server starts, reseat the operator information panel. If the

 

problem remains, replace the operator information panel.

 

2. Make sure that:

 

• The power cords are correctly connected to the server and to a working

 

electrical outlet.

 

• The type of memory that is installed is correct.

 

• The DIMM is fully seated.

 

• The LEDs on the power supply do not indicate a problem.

 

• The microprocessors are installed in the correct sequence.

 

3. Reseat the following components:

 

a. DIMMs

 

b. (Trained service technician only) Power switch connector

 

c. (Trained service technician only) Power backplane

 

4. Replace the following components one at a time, in the order shown, restarting

 

the server each time:

 

a. DIMMs

 

b. (Trained service technician only) Power switch connector

 

c. (Trained service technician only) Power backplane

 

d. (Trained service technician only) System board

 

 

Chapter 7. Troubleshooting 99

Page 111
Image 111
Lenovo 1048, 1046, 1047, 1045 manual Power problems