Table 2. Features and specifications
Microprocessor(s): Supports up to | Optical drive: | Environment: | |||||
two Intel Xeon | • Slim DVD/RW | • | Air temperature: | ||||
or |
| – | Server on: 10°C to 35°C (50°F | ||||
|
|
| |||||
specific type and speed information | Hard disk drive expansion bays |
|
| to 95°F); altitude: 0 to 914.4 m | |||
about the microprocessor, use |
|
| (3 000 ft) | ||||
(depending on the model): |
|
| |||||
the Setup Utility program. See |
| – | Server off: 10°C to 43°C (50°F | ||||
|
|
| |||||
“Using the Setup Utility program” on | Up to eight |
|
| to 109.4°F); maximum altitude: | |||
page 75. For a list of the supported |
|
| 2 133.6 m (7 000 ft) | ||||
hard disk drives |
|
| |||||
microprocessors for your server, go to |
| – | Shipping: | ||||
|
|
| |||||
http://www.lenovo.com/thinkserver. | Expansion slots: |
|
| to 140°F) | |||
On the ThinkServer systems page, | • | Humidity: | |||||
|
| ||||||
click Products ➙ Options ➙ | • One PCI Express x16 card slot |
| – | Server on: up to 80%, | |||
ThinkServer Processors. | on the system board for a riser |
|
| ||||
|
| card assembly (there are three PCI |
| – | Server off: up to 80%, | ||
Memory modules: | Express x8 card slots on the riser |
|
| ||||
• | Minimum system memory: 2 GB | card assembly) |
| – | Shipping and storage: up to | ||
• | Maximum system memory: 64 GB |
|
|
|
| 93%, | |
| (eight memory slots, each with one | Power supply: | • | Particulate contamination: | |||
| 8 GB RDIMM installed) | power supply / |
| Attention: Airborne particulates | |||
• | Types: ECC, 1333 MHz, DDR3 | power supply |
| ||||
| registered SDRAM DIMMs only |
|
|
| and reactive gases acting alone | ||
• | Slots: Eight dual inline memory | System fans: Four system fans |
| or in combination with other | |||
| module (DIMM) slots | with automatic |
| environmental factors such as | |||
• Supports 2 GB, 4 GB, and 8 GB | reduction technology |
| humidity or temperature might | ||||
| RDIMMs | Integrated functions: |
| pose a risk to the server. | |||
|
|
|
|
| |||
Integrated graphics card: | • Two |
|
|
| |||
• 8 MB video memory | controllers |
|
|
| |||
|
| • Six USB 2.0 connectors (two front |
|
|
| ||
Size: | and four rear) |
|
|
| |||
• | Height: 87.5 mm (3.45 inches) | • Two |
|
|
| ||
• | Width: 448 mm (17.64 inches) | • One serial port |
|
|
| ||
• | Depth: 683 mm (26.89 inches) | • One Video Graphics Array (VGA) |
|
|
| ||
• | Maximum weight: 30 kg (66.14 lb) | monitor connector |
|
|
| ||
| when fully configured |
|
|
|
|
| |
|
|
| |||||
RAID adapters: | Electrical input | Notes: | |||||
• | Onboard 1068E SAS RAID | • Input voltage: |
| 1. Power consumption and heat | |||
| controller | – | Low range: |
|
| output vary depending on the | |
• ThinkServer 8708ELP SAS RAID |
|
| number and type of optional | ||||
|
|
|
| ||||
| Minimum: 100 V ac |
|
| features installed and the | |||
| Adapter |
|
|
| |||
|
|
|
|
| |||
• | ThinkServer 8708EM2 RAID |
| Maximum: 127 V ac |
|
| ||
|
|
| features in use. | ||||
|
|
|
| ||||
| Adapter |
| Input frequency range: 50 to |
| 2. The sound levels were measured | ||
• ThinkServer RAID 700 Adapter |
| 60 Hz |
| ||||
|
|
| in controlled acoustical | ||||
– | High range: |
|
| ||||
|
|
|
| environments according to | |||
|
|
| Minimum: 200 V ac |
|
| the procedures specified by the | |
|
|
|
|
| American National Standards | ||
|
|
| Maximum: 240 V ac |
|
| ||
|
|
|
|
| Institute (ANSI) S12.10 and | ||
|
|
| Input frequency range: 50 to |
|
| ISO 7779 and are reported in | |
|
|
|
|
| accordance with ISO 9296. | ||
|
|
| 60 Hz |
|
| ||
|
|
|
|
| Actual | ||
|
|
|
|
|
| ||
|
|
|
|
|
| given location might exceed the | |
|
|
|
|
|
| average values stated because | |
|
|
|
|
|
| of room reflections and other | |
|
|
|
|
|
| nearby noise sources. The | |
|
|
|
|
|
| noise emission level stated | |
|
|
|
|
|
| is the declared (upper limit) | |
|
|
|
|
|
|
|