Product overview
FRU tests
The following table shows the test for each FRU.
FRU | Applicable test | |
|
|
|
System board | 1. | Diagnostics |
| 2. | Diagnostics |
| 3. | If the docking station or the port replicator is |
|
| attached to the ThinkPad computer, undock |
|
| it. Place the computer on a horizontal |
|
| surface, and run Diagnostics |
|
| Devices |
| Note: Do not apply any physical shock to the | |
| computer while the test is running. | |
|
| |
Power | Diagnostics | |
| Adapter, Battery 1 (Battery 2) | |
|
|
|
LCD unit | 1. | Diagnostics |
| 2. | Interactive Tests |
|
|
|
Modem, MDC | 1. | Make sure the modem is set up correctly. |
or BMDC | 2. | Replace the modem jack and the modem |
|
| card in turn, and run the following test in |
|
| Diagnostics |
|
| a. Conexant Smart Modem Interrupt |
|
| b. Conexant Smart Modem Dialtone |
|
|
|
Audio | 1. | Interactive Tests |
| 2. | Diagnostics |
|
| Devices AC97 CODEC Test |
|
| |
Speaker | Interactive Tests | |
|
|
|
PC Card slots | 1. | Diagnostics |
| 2. | Insert a PC Card Wrap Plug into every PC |
|
| Card Slot, and run Diagnostics |
|
| Systemboard |
|
|
|
Keyboard | 1. | Diagnostics |
|
| Keyboard |
| 2. | Interactive Tests |
|
| |
TrackPoint or | If the TrackPoint does not work, check the | |
pointing device | configuration in the ThinkPad Configuration | |
| program. If the TrackPoint is disabled, select | |
| Enable to enable it. | |
| After you use the TrackPoint, the pointer may | |
| drift on the screen for a short time. This drift | |
| can occur when a slight, steady pressure is | |
| applied to the TrackPointing Stick. This | |
| symptom is not a hardware problem. If the | |
| pointer stops after a short time, no service | |
| action is necessary. | |
| If enabling the TrackPoint does not correct the | |
| problem, continue with the following: | |
| v Interactive Tests | |
|
|
|
(continued)