195Operations - TN5250E SETUP: SCS OPTIONS > IDB Second Char (IDB Option 9)
IDB SecondChar (IDBOption 9)
This SCS Options > CSC Characters option defines the second
character in the CSC (Command String Characters) sequence. The
CSC is a unique two-character sequence, which opens the internal
IDB editor in the SCS/TNe Emulation. It must be used every time
IDB commands are sent to the SCS/TNe Emulation. The CSC is
also used in front of the Lead-in characters defined with option 171
and 172. Last of all the CSC is also used for passing single hex val-
ues to the printer, e.g. &%1B = <esc>.
The IDB option value is an ASCII character in the decimal range 33
- 126. Refer to “Appendix B - ASCII Character Table” on page282
for a complete list of characters and their values.
User IDB command:
Not supported
Parameter:
Not supported
Option Value IDB Value User IDB parameter
% * 37 [percent] Not supported