Reference: LQ630H/CQ610H Hospital Operations (Cont.)

Note: Even if Scan Mode is enabled, the front panel channel keys cannot be used to turn ON the TV.

Note: The power indicator on the front panel of the TV has two different settings: one for when the TV is in standby and one for when the TV is turned ON. The Power Indicator option in the Option Menu enables you to define the behavior of the power indicator. For LQ630H TVs, the Standby Light default is OFF, while the Power Light default is ON. Note, however, if an LQ630H TV is in the default Hospital Mode, it is not possible to change the Power Indicator settings. This means that for LQ630H TVs, when Installer Menu Item 027 HOSPITAL MODE is set to 254, the power indicator will retain its default settings regardless of any changes made via the Power Indicator option in the Option Menu. For CQ610H TVs, both the Standby Light and Power Light defaults are ON, and the Power Indicator settings are not affected by the Hospital Mode.

Speaker Selection

The following table outlines speaker settings as determined by Installer Menu items 027 HOSPITAL MODE and 020 FEATURE LEVEL.

Item 027 HOSPITAL

Item 020 FEATURE

Audio Menu

Speaker

MODE Value

LEVEL Value

TV Speaker

 

 

0

0 ~ 24

OFF

None

 

 

 

 

 

 

0

0 ~ 24

ON

TV Only

 

 

 

 

 

 

0

64 ~ 65

N/A

Pillow Only

 

 

 

 

1 ~ 34

N/A

N/A

Pillow Only

 

 

 

 

 

65

~ 98

N/A

OFF

None

65

~ 98

N/A

ON

TV Only

 

 

 

 

 

129

~ 162

N/A

OFF

Pillow Only

 

 

 

 

 

129

~ 162

N/A

ON

Pillow & TV

 

 

 

 

 

Note: If the TV is in FTG Mode, the Audio Menu is no longer accessible.