18 Room Air Conditioner
Installation
Fixing Indoor Unit

Drill the piping hole with a ø50mm hole core drill.

Drill the piping hole at either the right or the left with

the hole slightly slanted to the outdoor side.

Drill a Hole in the Wall
5-7mm
(0.2~0.3")
Indoor
WALL
Outdoor
Plastic anchors
INSTALLATION GUIDE MAP
10mm

INSTALLATION GU

INSTAIIATION GUIDE MAP
Plastic anchors
INSTALLATION GUIDE MAP
INSTALLATION GUIDE MAP
Hanger hole
(Rear side of
the product)
3. Make a hole with a diameter of 6mm and
depth of 30-35mm by piercing a screw
point.
5. Drive the fore plastic anchors into drilled
points.
7. Hang the hole of product at the upper
screws, and remove the map. (Falling
attention)
9. Check the fixed product with light power.
1. Attach an Installation guide map on the
desired surface. 2. Look at suited horizon by horizontal
meter on the horizontal setting line, and
fix lightly the map by adhesive tape.
4.
Drill the pierted part as a diameter of 50mm
for connecting piping. (In case of piercing
rear surface)
6.
First, Drive the two points of the upper
parts by screws. (Leave 10mm for hanging
the product)
8. Drive the lower parts after facing the hole
of product with plastic anchors, and fix
completely the upper screws.
10.
In case of nothing wrong, connect the
pipe and the wire. (Refer to installation
manual)
Horizontality
I
NSTALLATION GUIDE MAP