Operation

8. Forced Operation

Operation procedures when the remote control can't be used.

The operation will be started if the power button is pressed.

If you want to stop operation, re-press the button.

 

 

 

 

ON/OFF

 

 

 

 

 

button

 

 

 

 

 

 

 

 

 

Cooling

 

Heat pump Model

 

 

 

 

 

 

 

 

 

Model

Room Temp. 76°F(24°C)

70°F(21°C) Room Temp. < 76°F(24°C)

Room Temp. < 70°F(21°C)

 

 

 

 

 

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

 

 

 

 

 

 

 

Indoor FAN Speed

High

High

Healthy Dehumidification Rule

High

 

 

 

 

 

 

 

Setting Temperature

72°F(22°C)

72°F(22°C)

74°F(23°C)

76°F(24°C)

 

 

 

 

 

 

Test operation

 

 

 

 

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room tempera- ture and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep".

If you want to stop the operation, re-press the button.

9. Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

So there is no need of activating this function by pressing any key or button.

In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.

High Speed

Helpful information

Fan speed and cooling capacity.

The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed.

High fan speed is recommended when you wish to cool the room quickly.

NOTICE

Auto restart function has set enable as factory default.

But customer can set up by following this instruction.

To be disable function

- Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) blinks 4 times.

To be enable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times.

42Room Air Conditioner

Page 42
Image 42
LG Electronics LA120CPO Auto restart, Forced Operation, Cooling Heat pump Model, Test operation, Helpful information