30 minutes

Operation

7.Cooling or Heating Mode with Sleep Mode Auto Control

When selecting the Cooling( ) or the Heating( ) combined with the Sleep Mode Auto Control(), the operation diagram is as following.

Cooling Mode with the Sleep Mode

The setting temperature will be automatically raised by 2°F 30 minutes later and by 4°F 1 hour later.

The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

30 minutes

INTAKE AIR TEMP.

 

 

 

 

2°F

 

 

 

 

 

SETTING TEMP. +1°F

 

 

 

2°F

 

 

 

 

 

 

(Compressor ON)

 

 

 

 

 

SETTING TEMP. -1°F

 

More than

 

More than

 

(Compressor OFF)

 

 

 

 

 

3 minutes

 

3 minutes

 

INDOOR FAN SPEED

Low

Low

Low

Low

Low

COMPRESSOR

ON

OFF

ON

OFF

ON

Heating Mode with the Sleep Mode(only Heating Model)

The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

INTAKE AIR TEMP.

 

 

 

 

 

 

SETTING TEMP. +6°F

 

 

 

 

 

 

(Compressor OFF)

 

 

 

 

 

 

SETTING TEMP.

 

 

 

 

 

 

(Compressor ON)

 

More than

 

More than

 

More than

 

 

3 minutes

 

3 minutes

 

3 minutes

INDOOR FAN SPEED

Med

Low or OFF

Med

Low or OFF

Med

Low or OFF

COMPRESSOR

ON

OFF

ON

OFF

ON

OFF