10.1.2 Basic Setting of Tachyon for RF Calibration & Test

[ System Option Setting]

[ User Model Selection]

Procedure

1.Click “Tachyon_xxx.exe” in below directory to execute Tachyon program. “C:\LGE\Tachyon\”

2.Click “System Option Setting” icon in the menu to set COM port.

Select “UART Port” that can communicate with phone in the Shield Box 1 message. Click the “OK” button.

3.Click “User Model Selection” icon in the menu to set model configuration. Do double-click model/buyer name that you want to calibrate and test. Click the “Select” button.