2.2.4 SHROUD
1.Remove the axial fan. (Refer to section 2.2.3)
2.Remove the 4 screws which fasten the condenser with the shroud and the basepan. (See Figure 11)
3.Remove the shroud.
4.
2.3. ELECTRICAL PARTS
2.3.1 OUTDOOR MOTOR
1.Remove the clamp cord and disconnect a wire housing in control box. (Refer to section 2.1.2)
2.Remove the axial fan. (Refer to section 2.2.3)
3.Remove the 2 screws which fasten the motor. (See Figure 14)
4.Remove the motor
5.
2.3.2INDOOR MOTOR (Refer to section 2.2.2)
2.3.3COMPRESSOR
1.Discharge the refrigerant system using a refrigerant recovery system.
If there is no valve to attach the recovery system, install one (such as a WATCO
2.Disconnect the 3 leads from the compressor.
3.After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections.
4.Remove the 3 nuts and the 3 washers which fasten the compressor. (See Figure 15)
5.Remove the compressor.
6.
Figure 13
Figure 14
Figure 15
2.3.4 CAPACITOR
1. Remove the control box. (Refer to section 2.1.2)
2. Remove 1 screw and disconnect the leads which connected to the box type capacitor.
(See Figure 16)
3. Remove 1 screw and the clamp which fastens the
4. Disconnect all the leads of capacitor terminals.
5.
| Figure 16 |
|
|
Copyright ©2008 LG Electronics. Inc. All right reserved. | - 12 - |
Only for training and service purposes | LGE Internal Use Only |
|