LG Electronics LP121CEM-Y8 manual Subbase, Installation, Description, Receiving, Hazardous Voltage

Models: LP121CEM-Y8

1 48
Download 48 pages 50.4 Kb
Page 36
Image 36
Subbase

5.Replace the escutcheon with the one from this kit by inserting the tabs at the top of the escutcheon into the retaining holes and laying the escutcheon flat on the control panel.

6.Replace the front by reversing steps 1 through 4.

7.Store the control knobs and escutcheon just removed from the unit for possible reinstallation if the wall thermostat is no longer desired.

Figure 56

Escutcheon

Installation

The installation and servicing of the equipment referred to in this booklet should be performed by qualified, experienced technicians.

Manual background WARNING

Hazardous Voltage!

Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury.

Important Note:

The unit OFF switch does not disconnect all electrical power to this unit.

CAUTION

Use Copper Conductors Only!

Unit terminals are not designed to accept other types of conductors. Failure to use copper conductors may result in equipment damage.

Subbase

Part No: AYSB1101 (230/208V 20A)

AYSB2101 (230/208V 30A)

Description

The subbase may be installed on the wall sleeve before or after installing the wall sleeve. The subbase is prewired. Electrical connections can be made on the left side after the access cover is removed. A grounding screw is provided.

Receiving

Upon receipt of the product, inspect the shipping carton for signs of visible damage. Report any damage or shortage to the carrier and note it on the delivery receipt. The unit must be stored in its original shipping carton in a dry, secure place prior to its installation and use.

Note:

When using a subbase, the wall sleeve must be installed a minimum of 3-1/4inches (83 mm) above a finished floor and a minimum of 2-3/4inches (70 mm) from a finished wall.

1.Remove parts B and C (Figure 58, next page) from the subbase and join together using two metal screws provided. This assembly now becomes the right front cover (Part F) of the subbase. (Figure 57, next page)

2.Position subbase under the front of the wall sleeve.

3.Align the back edge of the flange on cover A (Figure 58, next page) to front of the wall sleeve flange. (Figure 59, next page)

4.Drill four 1/8 inch holes in wall sleeve to line up with holes in subbase. (Figure 58, Location D, next page) Mount subbase to wall sleeve with four sheet metal screws provided with kit. (Figure 58, Location D, next page)

5.Remove the left front cover from the subbase. (Figure 58, Part A, next page)

6.Position skirting on each side of wall sleeve to prevent the entry of foreign materials. Trim skirting to desired length. Attach skirting with four sheet metal screws provided with kit. (Figure 58, Location E, next page)

7.Wire subbase for appropriate voltage (Figure 60, next page).

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 36 -

Only for training and service purposes

LGE Internal Use Only

 

Page 36
Image 36
LG Electronics LP121CEM-Y8 manual Subbase, Installation, Description, Receiving, Hazardous Voltage, Important Note