Figure 38

Spraying

Tube

Pump

assembly

Tube #1

Rubber

elbows(3)

Tube #2

15. Assembly the unit back following the reverse order of disassembly.

NOTE: All tube should be inserted into rubber elbows by at least 1/2 inch

Figure 39

14. Connect the condensate pump to the ICR

Figure 40

relay of the terminal of the board as shown

 

in fig. 40 Make sure to fasten the pump

 

wire through the wire clip on the back side

 

of the control barrier as shown in fig. 39

 

Copyright ©2008 LG Electronics. Inc. All right reserved.

- 27 -

Only for training and service purposes

LGE Internal Use Only

 

Page 27
Image 27
LG Electronics LP121CEM-Y8 manual Spraying